User's Manual

Table Of Contents
Product Manual - RFID Reader UF70 Certum 141
Chapter 7
Operation
Parameter 122
(0x7A)
Communications standard
The communications standard is selected by this parameter (as far as possible
and enabled by the license).
Value range: 0x00 to 0x07
0x00: No communications standard
0x01: Auto detect
0x02: EN302208
0x03: EN302208_LBT
0x04: FCC
0x05: Own special settings
0x06: China
0x07: Thailand
Default: 0x01
Parameter 123
(0x7B)
ETSI Power Check Over All Allowed Channels
With this parameter, the performance check is conducted via the set channels.
Value range: 0x00 (false) and 0xFF (true)
Default: 0x00 (false)
Parameter 124
(0x7C)
Comm Standard Center Freq CH0
Parameters for the communications standard "specific".
Mid-frequency channel 0 in kHz
Value range: 0 to 1,048,575 kHz
Default: 0x00000000
Parameter 125
(0x7D)
Comm Standard Channel Width
Parameters for the communications standard "specific".
Channel width in kHz
Value range: 0 to 65,535 kHz
Default: 0x0000
Parameter 126
(0x7E)
Comm Standard Max Channel Time
Parameters for the communications standard "specific".
Maximum channel dwell time in ms
Value range: 10 to 65,535 ms
Default: 0x0000