User's Manual
Table Of Contents
- Product Manual RFID Reader UF70 Certum
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- X or URX - Read data area
- URY - Read data area (defined EPC code)
- M - EPC scanning
- URB - EPC Bulk reading
- W - Write EPC code
- UWW - Write data range of all EPC transponders
- UWZ - Write data range of all EPC- transponders (defined EPC code)
- UMW - Write data range of all EPC transponders masked
- UMZ - Write data range of all EPC- transponders (defined EPC code) masked
- UBW - Erase block of all EPC transponders
- UBZ - Erase block of all EPC transponders (defined EPC code)
- ULW - Locking all EPC transponders
- ULZ - Locking all EPC transponders (defined EPC code)
- UKW - Killing all EPC transponders
- UKZ - Killing all EPC transponders (defined EPC code)
- T and UAM - Enable read polling EPC
- UAA - Enable Read Polling Raw
- UAX - Polling Read Data
- UAW - Polling Write Data
- UAZ - Polling Write Masked Data
- UAB - Erase Block
- UAL - Lock EPC
- UAK - Kill EPC transponder
- UAR - Polling transponder rate
- UAE - End polling
- UCX - Activate polling NXP- UCODE-G2X Read Protect
- UCN - Activate polling NXP- UCODE-G2X Reset Read Protect
- UCC - Activate Polling NXP- UCODE-G2X Change EAS
- UCE - Activate polling NXP- UCODE-G2X EAS alarm
- UFW - Set filter data
- UFR - Read filter data
- UFP - Set filter
- UFG - Read filter data
- UGL - Read list of radio profiles
- UGP - Read active radio profile
- UPP - Set active radio profile
- UNH - Hardware reset
- UNR or N - Software reset
- UPE - Factory Reset/Factory Setting
- F - Parameter query
- P - Set parameter
- N - Reset
- UGK - Determine active parameter set
- UPK - Define the active parameter set
- UGD - Determine default parameter set
- UPD - Define default parameter set
- B - Sensor status
- O - Set output
- Q - Queries of the output status
- E - Error message
- H - Heartbeat
- UVR or V - Query software version
- UGT - Read UTC time
- UPT - Set UTC time
- Sensor triggered automatic reading
- 7.2.4 Parameters
- Parameter 0 (0x00)
- Parameter 01 (0x01)
- Parameter 03 (0x03)
- Parameter 04 (0x04)
- Parameter 06 (0x06)
- Parameter 07 (0x07)
- Parameter 08 (0x08)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 21 (0x15)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 28 (0x1C)
- Parameter 29 (0x1D)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 39 (0x27)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 93 (0x5D)
- Parameter 94 (0x5E)
- Parameter 95 (0x5F)
- Parameter 96 (0x60)
- Parameter 97 (0x61)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 100 (0x64)
- Parameter 101 (0x65)
- Parameter 102 (0x66)
- Parameter 103 (0x67)
- Parameter 104 (0x68)
- Parameter 105 (0x69)
- Parameter 106 (0x6A)
- Parameter 107 (0x6B)
- Parameter 108 (0x6C)
- Parameter 109 (0x6D)
- Parameter 110 (0x6E)
- Parameter 111 (0x6F)
- Parameter 112 (0x70)
- Parameter 113 (0x71)
- Parameter 114 (0x72)
- Parameter 115 (0x73)
- Parameter 116 (0x74)
- Parameter 117 (0x75)
- Parameter 118 (0x76)
- Parameter 119 (0x77)
- Parameter 120 (0x78)
- Parameter 121 (0x79)
- Parameter 122 (0x7A)
- Parameter 123 (0x7B)
- Parameter 124 (0x7C)
- Parameter 125 (0x7D)
- Parameter 126 (0x7E)
- Parameter 127 (0x7F)
- Parameter 128 (0x80)
- Parameter 129 (0x81)
- Parameter 130 (0x82)
- Parameter 131 (0x83)
- Parameter 132 (0x84)
- Parameter 133 (0x85)
- Parameter 134 (0x86)
- Parameter 135 (0x87)
- Parameter 136 (0x88)
- Parameter 137 (0x89)
- Parameter 138 (0x8A)
- Parameter 139 (0x8B)
- Parameter 140 (0x8C)
- Parameter 141 (0x8D)
- Parameter 142 (0x8E)
- Parameter 143 (0x8F)
- Parameter 144 (0x90)
- Parameter 145 (0x91)
- Parameter 146 (0x92)
- Parameter 147 (0x93)
- Parameter 148 (0x94)
- Parameter 149 (0x95)
- Parameter 150 (0x96)
- Parameter 151 (0x97)
- Parameter 152 (0x98)
- Parameter 153 (0x99)
- Parameter 154 (0x9A)
- Parameter 155 (0x9B)
- Parameter 156 (0x9C)
- Parameter 157 (0x9D)
- Parameter 158 (0x9E)
- Parameter 159 (0x9F)
- Parameter 160 (0xA0)
- Parameter 161 (0xA1)
- Parameter 162 (0xA2)
- Parameter 163 (0xA3)
- Parameter 164 (0xA4)
- Parameter 165 (0xA5)
- Parameter 166 (0xA6)
- Parameter 167 (0xA7)
- Parameter 168 (0xA8)
- Parameter 169 (0xA9)
- Parameter 170 (0xAA)
- Parameter 171 (0xAB)
- Parameter 172 (0xAC)
- Parameter 173 (0xAD)
- Parameter 174 (0xAE)
- Parameter 175 (0xAF)
- Parameter 176 (0xB0)
- Parameter 177 (0xB1)
- Parameter 178 (0xB2)
- Parameter 179 (0xB3)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- Index
Product Manual - RFID Reader UF70 Certum 158
Chapter 8
Service and Troubleshooting
8.4 Error codes
Error
ID
Name Description Possible causes Correcting action
0 none no error not used no
1 auto fail automatic reading is not
possible
1)
reader is still busy
with a former read or
write request
wait until the former request
is done
2 ex fail read or write initiated
from the host, and/or
other actions cannot be
carried out
1)
reader is still busy
with a former read or
write request
wait until the former request
is done
3 write fail data transfer to the tag
not possible
1)
reader is still busy
with a former read or
write request
wait until the former request
is done
4 no tag no tag or antenna
installed
no readable tag at
the reading range
bring a tag into the range of
the antenna; verify type and
function of the tag
antenna is not
connected correctly
check connection of the
antenna
bad orientation
between antenna and
tag
check orientation between
antenna and tag (see
section antenna installation
and antennas)
antenna is not tuned perform an antenna tuning
(see section installation ->
DIP switches)
disrupting field at
transmitting freqency
check surronding of antenna
for possible disrupting
sources (monitors , servo
motors...)
antenna is damaged
or too close to metal
replace antenna, verify
antenna installation
5 invalid invalid parameter or
data
data sent with a
command are wrong
check syntax and data of
command
sent parameter is not
implemented or out
of range
check syntax and value of
parameter