User's Manual

Table Of Contents
Product Manual - RFID Reader UF70 Certum 36
Chapter 6
Installation
6.8 External input and output (optional)
The following I/O versions are possible:
A digital input and output can be connected to each antenna port.
A 3 wire sensor or dry contact is possible as the input.
The output can operate a LED without a series resistor or directly switch 5 V DC.
6.9 Commissioning
6.9.1 Required operating conditions
The following two conditions must be fulfilled for operating the device:
6.9.2 Parameters of the serial interface
Baudrate 57,600
Data bits 8
Stop bit 1
Parity No
An antenna must be connected correctly to the reader.
Connect the power supply and switch on the device (if a POE is not used).
The transponder must be located within the individual reading/writing
range of the antenna (for testing)!