User's Manual
Table Of Contents
- Product Manual RFID Reader UF80
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- URY - Read data range (defined EPC code)
- M - Scan EPCs
- W - Write EPC code
- UWZ - Write data range of all EPC transponders (defined EPC code)
- ULZ - Locking all EPC transponders (defined EPC code)
- F - Query parameters
- P - Set parameter
- N - Reset
- O - Set output
- E - Error message
- H - Heartbeat
- V - Query software version
- K - Polling
- UFD - Query DHCP Enabled
- UPD - Set DHCP Enabled
- UFI - Query network settings
- UPI - Set network settings
- UFN - Query host name
- UPN - Set host name
- 7.2.4 Parameter
- Parameter 4 (0x04)
- Parameter 6 (0x06)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 16 (0x10)
- Parameter 39 (0x27)
- Parameter 43 (0x2B)
- Parameter 47 (0x2F)
- Parameter 48 (0x30)
- Parameter 50 (0x32)
- Parameter 64 (0x40)
- Parameter 65 (0x41)
- Parameter 66 (0x42)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 118 (0x76)
- Parameter 123 (0x7B)
- Parameter 158 (0x9E)
- Parameter 162 (0x02)
- Parameter 163 (0x00)
- Parameter 176 (0xB0)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
- Index
Product Manual - RFID Reader UF80 29
Chapter 6
Installation
6.7 Ethernet interface 10/100 BaseT
Pin assignment
Ethernet socket
M12
D coded
6.8 Commissioning
6.8.1 Required operating conditions
To operate the reader, the following requirements must be met:
6.8.2 Brooks Device Discoverer
The 10/100 BaseT Ethernet interface has the following default settings:
DHCP mode OFF
IP address 10.73.254.211
Gateway address 10.73.254.254
Subnet mask 255.255.254.0
TCP/IP 3241
If DHCP is enabled and the DHCP Server is not available, the device initializes the
Ethernet connection with the following values:
IP address 169.254.MAC5.MAC6
Gateway 169.254.MAC5.254
Subnet mask 255.255.255.0
Primary DNS Server IP 0.0.0.0
Secondary DNS Server I 0.0.0.0
(MAC address MAC1:MAC2:MAC3:MAC4:MAC5:MAC6)
Pin Signal
1 TX+
2 RX+
3 TX-
4 RX-
An antenna must be connected correctly to the reader.
The power supply must be connected.
The transponder must be located within the individual read/write range of
the antenna.