User's Manual

Table Of Contents
Product Manual - RFID Reader UF80 29
Chapter 6
Installation
6.7 Ethernet interface 10/100 BaseT
Pin assignment
Ethernet socket
M12
D coded
6.8 Commissioning
6.8.1 Required operating conditions
To operate the reader, the following requirements must be met:
6.8.2 Brooks Device Discoverer
The 10/100 BaseT Ethernet interface has the following default settings:
DHCP mode OFF
IP address 10.73.254.211
Gateway address 10.73.254.254
Subnet mask 255.255.254.0
TCP/IP 3241
If DHCP is enabled and the DHCP Server is not available, the device initializes the
Ethernet connection with the following values:
IP address 169.254.MAC5.MAC6
Gateway 169.254.MAC5.254
Subnet mask 255.255.255.0
Primary DNS Server IP 0.0.0.0
Secondary DNS Server I 0.0.0.0
(MAC address MAC1:MAC2:MAC3:MAC4:MAC5:MAC6)
Pin Signal
1 TX+
2 RX+
3 TX-
4 RX-
An antenna must be connected correctly to the reader.
The power supply must be connected.
The transponder must be located within the individual read/write range of
the antenna.