User's Manual
Table Of Contents
- Product Manual RFID Reader UF80
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- URY - Read data range (defined EPC code)
- M - Scan EPCs
- W - Write EPC code
- UWZ - Write data range of all EPC transponders (defined EPC code)
- ULZ - Locking all EPC transponders (defined EPC code)
- F - Query parameters
- P - Set parameter
- N - Reset
- O - Set output
- E - Error message
- H - Heartbeat
- V - Query software version
- K - Polling
- UFD - Query DHCP Enabled
- UPD - Set DHCP Enabled
- UFI - Query network settings
- UPI - Set network settings
- UFN - Query host name
- UPN - Set host name
- 7.2.4 Parameter
- Parameter 4 (0x04)
- Parameter 6 (0x06)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 16 (0x10)
- Parameter 39 (0x27)
- Parameter 43 (0x2B)
- Parameter 47 (0x2F)
- Parameter 48 (0x30)
- Parameter 50 (0x32)
- Parameter 64 (0x40)
- Parameter 65 (0x41)
- Parameter 66 (0x42)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 118 (0x76)
- Parameter 123 (0x7B)
- Parameter 158 (0x9E)
- Parameter 162 (0x02)
- Parameter 163 (0x00)
- Parameter 176 (0xB0)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
- Index
Product Manual - RFID Reader UF80 42
Chapter 7
Operation
URY - Read data
range (defined EPC
code)
The URY command starts the reading of a defined data range of the current EPC
transponders which have a defined EPC code. Several EPC transponders can be
located in the reading area of the antenna when using this command.
1) These data are displayed in the order listed for each identified EPC
transponder.
2) The response of the transponder is optional and only appears at result "00".
3) The result and Ex flag is only available in the first transmitted message in
messages with several frames.
Example: Read access password
>> URY01060102030405060708090A0BCD00000000000200000002
<< ury000000101060102030405060708090A0BCD000200000000
Host reader
CMD
Reader
ID
Head
ID
EPC
Access
word
Memory
bank
Memory
address
Number of
data words
URY 1 byte 1 byte (2n+1)*2
bytes
8 bytes 2 bytes 8 bytes 2 bytes
Reader host
Overhead response telegram
2)
Data of the participating EPC transponders
1) 2)
CMD
Reader
ID
Frame
ID
Result
3)
Ex flag
3)
Exten-
sions
EPC
Trans-
ponder
error
code
Number
N data
words
Data
words
ury 1 byte 2 bytes 2 bytes 2 bytes 0-12
bytes
(2n+1)
*2
bytes
2 bytes 2 bytes N*4
bytes