User's Manual
Table Of Contents
- Product Manual RFID Reader UF80
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- URY - Read data range (defined EPC code)
- M - Scan EPCs
- W - Write EPC code
- UWZ - Write data range of all EPC transponders (defined EPC code)
- ULZ - Locking all EPC transponders (defined EPC code)
- F - Query parameters
- P - Set parameter
- N - Reset
- O - Set output
- E - Error message
- H - Heartbeat
- V - Query software version
- K - Polling
- UFD - Query DHCP Enabled
- UPD - Set DHCP Enabled
- UFI - Query network settings
- UPI - Set network settings
- UFN - Query host name
- UPN - Set host name
- 7.2.4 Parameter
- Parameter 4 (0x04)
- Parameter 6 (0x06)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 16 (0x10)
- Parameter 39 (0x27)
- Parameter 43 (0x2B)
- Parameter 47 (0x2F)
- Parameter 48 (0x30)
- Parameter 50 (0x32)
- Parameter 64 (0x40)
- Parameter 65 (0x41)
- Parameter 66 (0x42)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 118 (0x76)
- Parameter 123 (0x7B)
- Parameter 158 (0x9E)
- Parameter 162 (0x02)
- Parameter 163 (0x00)
- Parameter 176 (0xB0)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
- Index
Product Manual - RFID Reader UF80 49
Chapter 7
Operation
F - Query
parameters
The F command is used to query individual parameters ( Parameter) of the
device. The number of the parameter is transmitted in "Parameter No.". The
response contains the parameter number and value. The parameter number and
the value are specified in HEX format, for example
Parameter 11 (0x0B).
1) If no parameter number is specified, the reader will provide all reader
parameters. A single response telegram is then sent for each parameter. The
parameter value can be multi-digit (N>=1)!
Example:
15.09.2011 09:44:31 Info: Send Message: F062
15.09.2011 09:44:31 Info: Message Stream Sent: 53 30 34 46 30 36 32 0D
15.09.2011 09:44:31 Info: Message Stream Received: 53 30 36 66 30 36 32 33
36 0D
15.09.2011 09:44:31 Info: Received Message: f06236
Query of the temperature of the processor value 0x36 equals 54 °C
Host reader
CMD Reader ID
Parameter no.
1)
F 1 byte 2 bytes
Reader host
CMD Reader ID Parameter no. Parameter value
f 1 byte 2 bytes N*2 bytes