User's Manual
Table Of Contents
- Product Manual RFID Reader UF80
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- URY - Read data range (defined EPC code)
- M - Scan EPCs
- W - Write EPC code
- UWZ - Write data range of all EPC transponders (defined EPC code)
- ULZ - Locking all EPC transponders (defined EPC code)
- F - Query parameters
- P - Set parameter
- N - Reset
- O - Set output
- E - Error message
- H - Heartbeat
- V - Query software version
- K - Polling
- UFD - Query DHCP Enabled
- UPD - Set DHCP Enabled
- UFI - Query network settings
- UPI - Set network settings
- UFN - Query host name
- UPN - Set host name
- 7.2.4 Parameter
- Parameter 4 (0x04)
- Parameter 6 (0x06)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 16 (0x10)
- Parameter 39 (0x27)
- Parameter 43 (0x2B)
- Parameter 47 (0x2F)
- Parameter 48 (0x30)
- Parameter 50 (0x32)
- Parameter 64 (0x40)
- Parameter 65 (0x41)
- Parameter 66 (0x42)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 118 (0x76)
- Parameter 123 (0x7B)
- Parameter 158 (0x9E)
- Parameter 162 (0x02)
- Parameter 163 (0x00)
- Parameter 176 (0xB0)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
- Index
Product Manual - RFID Reader UF80 52
Chapter 7
Operation
O - Set output The O command changes the status of the corresponding output. To keep the
current status of an output, use value 3 - keep status.
The outputs can always be set, irrespective of whether the corresponding I/O has
been configured as input or output.
Output state:
LED 1 -> red LED
LED 2 -> green LED
LED 3 -> yellow LED
Example:
18.08.2011 12:56:20 Info: Send Message: O013333
18.08.2011 12:56:20 Info: Message Stream Sent: 53 30 37 4F 30 31 33 33 33
33 0D
18.08.2011 12:56:20 Info: Message Stream Received: 53 30 33 6F 30 31 0D
18.08.2011 12:56:20 Info: Received Message: o01
everything remains off and unchanged
18.08.2011 12:56:38 Info: Send Message: O010123
18.08.2011 12:56:38 Info: Message Stream Sent: 53 30 37 4F 30 31 30 31 32
33 0D
18.08.2011 12:56:38 Info: Message Stream Received: 53 30 33 6F 30 31 0D
18.08.2011 12:56:38 Info: Received Message: o01
Buzzer off, green LED on, yellow LED flashes, red LED remains off
Host reader
CMD Reader ID Head ID
Output state
Buzzer Green LED
Yellow
LED
Red LED
O 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte
Reader host
CMD Reader ID Head ID
o 1 byte 1 byte