Product Manual - RFID Reader UF80 65
Chapter 7
Operation
Parameter 4
(0x04)
Delay time
If a confirmation is not sent by the host, the device waits this time span before it
sends the message to the host again. The number of repetitions is defined in
parameter 6 (MaxRepeat).
0x0A - 0xFA (0.1 s) 1 - 25 s
Default: 0x32
Parameter 6
(0x06)
MaxRepeat
If a confirmation is not sent by the host, the device repeats the message
according to the set value. Only then is an error message sent.
0x00 - 0x1F
Default: 0x03
Parameter 11
(0x0B)
Reader ID
This parameter defines the address of the device in the ASC-I1 protocol. We
recommend keeping the default setting since the module can be identified via the
hardware interface.
0x00 - 0x0E
Default: 0x00
Parameter 12
(0x0C)
Acknowledgment error message
This parameter defines whether an error message must be confirmed or not.
0x00 - no confirmation is expected
0x01 - a confirmation is expected
Default: 0x01
Parameter 16
(0x10)
Attenuation of transmission output
This parameter defines the attenuation of the transmission output in dBm.
Attenuation 0x00 -> 26.5 dBm = approx. 450 mW
Attenuation 0x0A -> 26.5 dBm - 10 dBm = approx. 50 mW
Attenuation 0x13 -> 26.5 dBm - 19 dBm = approx. 4 mW
Default: 0x13