Product Manual - RFID Reader UF80 66
Chapter 7
Operation
Parameter 39
(0x27)
Polling frequency
When polling, the reader scans the set transponder type. All detected
transponders are read out via the set communication port (see K command). If
the parameter is set to zero, there is no polling.
0x00 - 0xFF (5 ms steps)
Default: 0x00
Parameter 43
(0x2B)
Polling fallout
This number indicates the number of times a transponder is not read in
succession when polling before it is considered "not detected". Only transponders
that are not detected are reported to the host during another read operation that
is successful.
0x00 - 0xFF
Default: 0x03
Parameter 47
(0x2F)
Polling mode
Bit 0 (0x01) If this bit is set, the buzzer is turned on after a successful
read operation.
Bit 1 (0x02) not used
Bit 2 (0x04) not used
Bit 3 (0x08) not used
Bit 4 (0x10) If the inventory has been successful, the EPC is read out.
Bit 5 (0x20) not used
Bit 6 (0x40) not used
Bit 7 (0x80) not used
Default: 0x11
Parameter 48
(0x30)
Buzzer delay
This parameter defines the minimum amount of time the buzzer remains on.
0x00 - 0xFF (factor 50 ms)
Default: 0x32
Parameter 50
(0x32)
Buzzer volume
0x00 ... off
0x01 ... volume 1
0x02 ... volume 2
0x03 ... volume 3
Default: 0x01