User's Manual
Table Of Contents
- Product Manual RFID Reader UF80
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- URY - Read data range (defined EPC code)
- M - Scan EPCs
- W - Write EPC code
- UWZ - Write data range of all EPC transponders (defined EPC code)
- ULZ - Locking all EPC transponders (defined EPC code)
- F - Query parameters
- P - Set parameter
- N - Reset
- O - Set output
- E - Error message
- H - Heartbeat
- V - Query software version
- K - Polling
- UFD - Query DHCP Enabled
- UPD - Set DHCP Enabled
- UFI - Query network settings
- UPI - Set network settings
- UFN - Query host name
- UPN - Set host name
- 7.2.4 Parameter
- Parameter 4 (0x04)
- Parameter 6 (0x06)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 16 (0x10)
- Parameter 39 (0x27)
- Parameter 43 (0x2B)
- Parameter 47 (0x2F)
- Parameter 48 (0x30)
- Parameter 50 (0x32)
- Parameter 64 (0x40)
- Parameter 65 (0x41)
- Parameter 66 (0x42)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 118 (0x76)
- Parameter 123 (0x7B)
- Parameter 158 (0x9E)
- Parameter 162 (0x02)
- Parameter 163 (0x00)
- Parameter 176 (0xB0)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
- Index
Product Manual - RFID Reader UF80 68
Chapter 7
Operation
Parameter 66
(0x42)
MaxRepeat scan configuration transponder
The parameter determines the number of times a successful read operation of the
configuration transponder has to be repeated during the start procedure, before
its settings are analyzed.
0x00 … Not necessary to repeat the read operation, it is sufficient to
read the configuration transponder once.
0x01 - 0x0A … 1 to 10 successful repetitions of the read operation are necessary
Default: 0x02
Parameter 98
(0x62)
Query temperature of the processor (read only)
This value can only be queried and provides the current temperature of the
processor in °C (signed byte value).
Parameter 99
(0x63)
Default parameter
This parameter is used to reset the reader to its default parameters.
Default: 0x00
Parameter 118
(0x76)
Extended result flag
This value determines which data of a detected transponder are also displayed.
Value range: see information unit "Ex flag" and "Extensions" in
Message items
Default: 0x01 (antenna port only)
Parameter 123
(0x7B)
Fine version (read only)
This parameter specifies the fine version of the software version.
Parameter 158
(0x9E)
Tag comm initial Q
The initial Q results from the number of anticipated transponders (anticipated
transponder number = 2Q)
Value range: 0x00 to 0x0F
Default: 0x03
Parameter 162
(0x02)
UHF asic parameter Tx driver current (register 0x0B)
Sets the reader ASIC parameter "Tx driver current".
Values: 0x00 (low), 0x01 (mid), 0x02 (high)
Default: 0x02 (high)