User's Manual
Table Of Contents
- Product Manual RFID Reader UF80
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- URY - Read data range (defined EPC code)
- M - Scan EPCs
- W - Write EPC code
- UWZ - Write data range of all EPC transponders (defined EPC code)
- ULZ - Locking all EPC transponders (defined EPC code)
- F - Query parameters
- P - Set parameter
- N - Reset
- O - Set output
- E - Error message
- H - Heartbeat
- V - Query software version
- K - Polling
- UFD - Query DHCP Enabled
- UPD - Set DHCP Enabled
- UFI - Query network settings
- UPI - Set network settings
- UFN - Query host name
- UPN - Set host name
- 7.2.4 Parameter
- Parameter 4 (0x04)
- Parameter 6 (0x06)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 16 (0x10)
- Parameter 39 (0x27)
- Parameter 43 (0x2B)
- Parameter 47 (0x2F)
- Parameter 48 (0x30)
- Parameter 50 (0x32)
- Parameter 64 (0x40)
- Parameter 65 (0x41)
- Parameter 66 (0x42)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 118 (0x76)
- Parameter 123 (0x7B)
- Parameter 158 (0x9E)
- Parameter 162 (0x02)
- Parameter 163 (0x00)
- Parameter 176 (0xB0)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
- Index
Product Manual - RFID Reader UF80 69
Chapter 7
Operation
Parameter 163
(0x00)
UHF asic parameter Rx gain
Sets the reader ASIC parameter "Rx gain".
Default: 0x00 (decrease)
Parameter 176
(0xB0)
TCP keep alive
This parameter defines the time span – in steps of 10 s – in which the reader
checks an existing Ethernet connection to the host.
At a value of 0x00, a TCP keep alive check is deactivated.
Default: 0x06 (60 s)
7.3 Additional information
Value Register 0x05 Register 0x0A Register 0x0B
0x00 (decrease) 0x05 0x01 0x02
0x01 (low) 0x85 0x41 0x01
0x02 (mid) 0x85 0x81 0x01
0x03 (high) 0x85 0xC1 0x01
IMPORTANT
Never expose the device to extreme temperature fluctuations since otherwise
condensation develops in the device and causes damage.