User Manual

Installation and Operation Manual
X-VA-MT3809G-MT3810G-eng
Part Number: 541B182AAG
September, 2013 Models MT3809G & MT3810G
1-23
Section 1 Introduction
1-5-3 Microprocessor Transmitter with or without Inductive Alarms
This combined system provides both the sophistication of the
microprocessor along with the simplicity of one or two switch inductive
alarms. Specifications for the transmitter are as stated previously and
specifications for the front adjustable alarms are as described in the
section Inductive Alarm Switches.
Wiring diagrams
Refer to Figures 1-4, 1-6 and 1-8
For Division 1 explosion proof installations, the optional explosion proof
enclosure must be used. This enclosure does not use the auxiliary
terminal box, as shown on some of the installation diagrams. All
connections are made directly within the housing.
For Division 2 non-incendive installations, either the standard enclosure or
the explosion proof enclosure may be used.
For both Division 1 explosion proof and Division 2 non-incendive
installations, the barriers shown in the installation drawings are optional.
Wiring must be done in accordance with the applicable electrical codes,
i.e., NEC Chapter 5 and CEC Section 18, Canadian Electrical Code and
any local codes.
Transmitter accessories
General purpose and intrinsically safe HART compatible power supplies
are available in 120V and 240V.
Specifications - Traansmitters
PP
PP
P
ower Supplyower Supply
ower Supplyower Supply
ower Supply 22.8 to 30 Vdc: (2-wire current loop transmitter)
TT
TT
T
rr
rr
r
ansmitteransmitter
ansmitteransmitter
ansmitter 4-20 mA analog output with HART data. Update rate:
4 times per sec. Range: 3.8 to 22.0 mA.
TT
TT
T
wo wo
wo wo
wo
Alarm OutputsAlarm Outputs
Alarm OutputsAlarm Outputs
Alarm Outputs Optically isolated outputs assignable to alarms.
(open collector)(open collector)
(open collector)(open collector)
(open collector) Max. off-state voltage: 30 Vdc
• Max. off-state current: 0,05 mA
• Max. on-state voltage: 1.2 Vdc
• Max. on-state current: 20 mA
One Pulse OutputOne Pulse Output
One Pulse OutputOne Pulse Output
One Pulse Output Optically isolated. Scaleable to a variety of engineering unit systems (pulses per liter,
(open collector)(open collector)
(open collector)(open collector)
(open collector) gallons, etc.).
• Range: 1 Hz to 1 kHz
• Max. off-state voltage: 30 Vdc
• Max. off-state current: 0.05 mA
• Max. on-state voltage: 1.2 Vdc
• Max. on-state current: 20 mA
TT
TT
T
emperemper
emperemper
emper
aturatur
aturatur
atur
e Specificatione Specification
e Specificatione Specification
e Specification See Table 1-4
Electrical ConnectorElectrical Connector
Electrical ConnectorElectrical Connector
Electrical Connector M20 x 1,5 according to ISO (1/2" NPT, 3/4” NPT (F) or cable gland 8-12 mm optional)
LinearityLinearity
LinearityLinearity
Linearity Less than 1% at max. current.
TT
TT
T
emperemper
emperemper
emper
aturatur
aturatur
atur
e Ine In
e Ine In
e In
fluencefluence
fluencefluence
fluence Less than 0.04% per °C.
VV
VV
V
oltage Inoltage In
oltage Inoltage In
oltage In
fluencefluence
fluencefluence
fluence Less than 0.002% / Vdc.
Load Resistance InLoad Resistance In
Load Resistance InLoad Resistance In
Load Resistance In
fluencefluence
fluencefluence
fluence ± 0.1% full scale.