Installation and Operation Manual York Petite, Midi & Grande Multi Fuel Stoves Tested to EN 13240 TJ09C THIS APPLIANCE MUST BE INSTALLED AND COMMISSIONED BY A FULLY QUALIFIED, REGISTERED ENGINEER. A “Declaration of Completion” Certificate must be obtained for the installation and retained by the end user. Failure to comply with these requirements may void the warranty.
YORK MULTIFUEL STOVES INSTALLATION AND OPERATION MANUAL Thank You May we take this opportunity to thank you for choosing a York, cast iron Multi-fuel stove. Please take time to read this manual and follow the guidelines on how to install and operate your new stove, as we feel sure it will enable you to use it to its best advantage for many years. The term multi-fuel refers to the fact that the appliance is capable of burning both wood and coal.
INSTALLATION OF STOVE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION These instructions cover the basic principles to ensure the satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove.
Hearth Your stove must be installed on a solid, level non-combustible hearth and with a gap of at least 600mm from any combustible material such as beams or skirting. The hearth protrusion in front of the stove to carpets or wooden floors must be at least 300mm. As it is possible, that on opening the door of the stove for fuel to fall out, a fender must be fitted if the hearth is flush with the carpet. These are just a few hearth specifications.
If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used. These chimneys must be fitted in accordance with the manufacturer’s instructions and Building Regulations. The liner diameter must not be less than 6”. If the draw on the chimney is excessive, a flue draught stabiliser will help to slow this down.
must be paid to any build up of deposits in the flue and regular cleaning undertaken. Fuels such a bituminous coal, untreated wood or compressed paper are not smokeless or low volatiles fuel. To get the best transfer of heat from the stove into the room there are two factors to consider when installing into a fireplace recess. Firstly, the flue pipe from the stove must pass through either a top or back ‘register plate’.
STEP BY STEP GUIDE FOR FITTING NEW YORK FIREBRICK SETS Please remove Grate and Ash pan before fitting fire bricks STEP 1. Fit Left Side Brick first with angle facing rear of stove. Smooth side of cast facing inwards. STEP 3. Insert Baffle Brick with the cut outs towards the rear of stove and the smooth side facing downwards. Push to the top of stove with one hand while placing right side brick into position STEP 2. Insert Right Side Brick same as step 1. Then lay down flat on base casting. STEP 4.
Commission/Handover Ensure loose parts are fitted in accordance with the instructions for “Assembly” given above. On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and emitted safely to atmosphere. Do not run at full output for at least 24 hours.
OPERATION OF STOVE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THE STOVE Controls Layout York Grande Secondary Air Control (spinner control) Primary Air Control (push/pull lever) York Midi Secondary Air Control (spinner control) Primary Air Control (push/pull lever) Ash Pan The ash pan can be removed using the double end of the poker which fits under the top lip of the ash pan. Care must be exercised when opening the ash pan door as the handle and this part of the stove will be very hot.
Air-wash System This is a system where secondary air is drawn into the stove (by combustion) through the air control under the ash lip and deflected down the back face of the glass, thus preventing the smoke coming into contact with the glass. It does not mean that you will never have to clean the glass, but substantially lengthens the periods between having to do so. The air-wash system works best when burning dry wood at high temperature. Wet and pitchy wood will produce more deposits on the glass.
Curing the Stove Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean, is sound and free from any obstructions. This curing process may have been undertaken by your installer as part of the stoves’ commissioning and handover and the installer should have shown you how to operate the stove correctly.
Under NO circumstances burn ‘petroleum coke’ as it will burn out the internal grate and baffle plates in a very short period of time and may damage the stove beyond repair. Only burn dry, seasoned wood. This will give a good heat yield and help to keep the glass clean. A growing tree contains 50-95% water. Burning unseasoned wood turns most of the energy released into water vapour which goes into the flue and little heat is given off to the room.
BURNING WOOD LOGS If you are only burning wood logs, you may allow a bed of ash to build up on top of the grate to a level of about 20mm forming a flat surface on which the wood may burn. You will then use the “air-wash” bottom knob to provide the combustible air and control the burn rate of the fire. For fully open, pull the knob out towards yourself. By varying the length pulled you will be able to control the rate of burn – fully open being the fastest burn producing most heat.
Chimney Fires If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove has gone out. The chimney and flueways should then be cleaned.
Trouble-Shooting 1. Smoke comes out of the stove when the loading door is opened. • • The chimney cavity into which the 125mm flue pipe has been installed may be less than the minimum requirement. Deposits (soot) may have built up in the chimney and be restricting the flow of waste products. This flow rate is known as the ‘draw’. 2. The Stove does not produce the expected heat into the room.
ANNUAL SERVICE RECORD INSTALLATION DATE OF APPLIANCE: 1ST YEAR SERVICE completion date: SERVICE ENGINEER: COMPANY NAME: COMPANY ADDRESS: CONTACT NUMBER . REG. No. . . POSTCODE: 2ND YEAR SERVICE completion date: SERVICE ENGINEER: COMPANY NAME: COMPANY ADDRESS: . . REG. No. . . POSTCODE: 3RD YEAR SERVICE completion date: SERVICE ENGINEER: COMPANY NAME: COMPANY ADDRESS: . . REG. No. . . POSTCODE: 4TH YEAR SERVICE completion date: SERVICE ENGINEER: COMPANY NAME: COMPANY ADDRESS: . . REG. No. . .
LIMITED WARRANTY This appliance must be installed and commissioned by a fully qualified, registered engineer. A “Declaration of completion Certificate” must be obtained for the installation and retained by the end user. Failure to comply with these requirements may void your warranty. You, as the end user, have a contract by law with the supplier / dealer from whom you purchased the product.
York Petite Dimensions © 2007-2008 Broseley Fires Ltd
York Midi Dimensions © 2007-2008 Broseley Fires Ltd
York Grande Dimensions © 2007-2008 Broseley Fires Ltd