Technical information

© 2007-2008 Broseley Fires Ltd
PLEASE EXPLAIN TO THE CUSTOMER THESE LIGHTING AND
EXTINGUISHING PROCEDURES AND THAT IT IS NORMAL FOR THE STOVE
TO GIVE OFF ODOURS WHILST THE PAINT MATURES.
11. NOTE TO THE INSTALLATION ENGINEER
Please make sure the customer is familiar with the initial lighting and
operating procedures before leaving the site and that this instruction
booklet is left with them when the final commissioning is complete.
12. TEST FOR SPILLAGE
A spillage test MUST be made before the installed fire is left with the customer.
Carry out the test by first closing all doors and windows in the room containing the fire.
Ensure that the fire is burning at full rate for a minimum of 10-15 minutes.
Using a smoke match - run along the edge of the draught diverter, leave for a further 10
minutes and repeat test.
If there is an extractor fan in a nearby room the spillage test must be repeated with the
fan running and all connecting doors between the fire and fan left open.
If there are still problems, the chimney/flue may require attention. Disconnect the stove
and seek expert advice.
SPILLAGE MONITORING SYSTEM
This appliance is fitted with an atmospheric sensing spillage monitoring system, in the
form of an oxygen depletion sensing pilot. This is designed to shut down the fire within a
safe period if there is an excessive build up of products of combustion within the room
space. This would usually only occur if the flue path suffered severe blockage, and/or
ventilation was severely impeded.
THE FOLLOWING ARE IMPORTANT WARNINGS RELATIVE TO THE SPILLAGE
MONITORING SYSTEM
1. The installer must not attempt any adjustments to the spillage monitoring system.
2. There must be no attempt to disable the spillage monitoring system.
3. It is not possible to replace individual parts of the pilot assembly on the appliance
only a complete pilot assembly (including thermocouple) may be fitted in the
event of replacement being necessary. When the spillage monitoring system is
replaced, only complete and original manufacturers parts may be fitted.
Should the appliance turn itself off, wait for a minimum of 3 minutes before attempting to
re-light the appliance. In the event of your stove tripping out, consult your installation
engineer to have the flue/chimney checked.