Routine Maintenance
222
9
Replace the Reverse Roller 9
Your machine is equipped with a scan counter that automatically counts how many times the machine has
scanned. After approximately 200,000 scans, you may have to replace the Reverse Roller.
1 Open the Front Cover 1.
2 From the back of the machine, pinch the both sides of the Reverse Roller Cover 1 and pull the Cover
down.
3 To remove the Reverse Roller, grab its shaft and pull it toward you and out to the right 1.
1
1
1