Instruction manual

11. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
55
KE-436C
Memory switches (30 - 3F)
Turn the dial while pressing the STEP BACK switch to change the values.
Switch No.
Possible setting range
Units Initial value Explanation
memo-30 1 - 999 × 10ms 10
Time until feed mechanism starts moving after work clamp
has lifted.
memo-31 1 - 5 4
Changes the feed speed.
1 (Fast) ←→ 5 (Slow)
memo-32 3 - 7 3
Changes the possible sewing speed for a given stitch length.
3 (Fast) ←→ 7 (Slow)
3 (2,500/3 mm), 4 (2,300/3 mm), 5 (2,000/3 mm),
6 (1,800/3 mm), 7 (1,200/3 mm)
memo-33 1 - 10 × 7.5° 5
Changes the feed timing.
1 (Fast) 5 (Standard) 10 (Slow)
memo-34 1 - 5 stitch 1
Number of low-speed stitches sewn at 400 rpm at sewing
start.
memo-35 3 - 9 × 100rpm 4
Changes the sewing start speed for the number of stitches
specified by memo-34.
memo-36 −−
memo-37 0 - 3 0
Automatically corrects the gear speed when reading 2DD
disks.
0: No automatic correction
1: Read as BAS-311A data
2: Read as BAS-326A data
3: Read as BAS-341A, 342A data
ex. Read BAS-326A data by KE-436C Set memo-37=2.
memo-38 −−
memo-39 0 - 11 0
Changes the reference point for enlargement and reduction
using the operation panel.
0, 1: Center of work clamp,
2: Upper-left corner of work clamp,
3: Lower-left corner of work clamp,
4: Upper-right corner of work clamp,
5: Lower-right corner of work clamp, 6: Sewing start point,
7: Sewing end point, 8: Upper-left corner of sewing pattern,
9: Lower-left corner of sewing pattern,
10: Upper-right corner of sewing pattern,
11: Lower-right corner of sewing pattern
memo-3A 1 - 3 2
Changes the speed limit for the given sewing pitch when the
maximum speed remains constant.
1: Speed limit is increased for the given sewing pitch and the
sewing speed for that pitch is increased.
2: Standard
3: Speed limit is decreased for the given sewing pitch and the
sewing speed for thet pitch is decreased.
Note:
If sewing slippage occurs in places where a large sewing
pitch is used, reduce the setting to 3.
Furthermore, sewing slippage may occur in some cases if
setting 1 is used.
memo-3b 0 - 13 0
Changes the work clamp operating mode. (When set to “0”,
the mode is selected according to the settings for DIP
switches A-1 and A-2.) Refer to “12. Setting the work clamp
mode” for details on the setting values.
memo-3c 0 - 4 0
Changes the path taken when moving from the machine
home position to the start position.
0: Across inside of work clamp, 1: Top-left, 2: Bottom-left,
3: Bottom-right, 4: Top-right
memo-3d −−
memo-3E −−
memo-3F −−