Owner's Manual

5. USING THE OPERATION PANEL (BASIC OPERATIONS)
KE-430D, BE-438D 33
5-2. Setting the program number
The program number is set to 0 (feed home position check)
at the time of shipment from the factory.
1. Press the
or key (1) to select the program
number.
The program number will flash in the PROGRAM No.
display (2).
2. Depress the foot switch to the 2nd step.
The feed mechanism will move to the home position
and the program number will be accepted.
The program number will stop flashing and illuminate
steadily.
Note:
Once the setting is complete, be sure to carry out the
steps in "5-5./5-6. Checking the sewing pattern" to check
that the needle drop position is correct.
5-3. Setting the X-scale and Y-scale
The scales are set to 100 (%) at the time of shipment from
the factory.
1. Press the SELECT key (1) so that the X-SCALE
indicator (2) (for X-scale setting) or the Y-SCALE
indicator (3) (for Y-scale setting) is illuminated.
The setting value (%) will display in the menu display
(4).
* When memory switch no. 402 is set to "ON", the
settings will be displayed in units of mm.
2. Press the
or key (5) to set the scale (20 - 200).
The program number will flash in the PROGRAM No.
display (6).
3. Depress the foot switch to the 2nd step.
The feed mechanism will move to the home position
and the scale will be accepted.
The program number will stop flashing and illuminate
steadily.
Note:
Once the setting is complete, be sure to carry out the
steps in "5-5./5-6. Checking the sewing pattern" to check
that the needle drop position is correct.
5-4. Setting the sewing speed
The sewing speed is set to 2000 (rpm) at the time of
shipment from the factory.
1. Press the SELECT key (1) until the SPEED indicator (2)
illuminates.
• The setting value (rpm) will display in the menu
display (3).
2. Press the
or key (4) to set the sewing speed.
(Sewing speed setting values KE-430D: 400 - 3200,
BE-438D: 400 - 2700)
4436Q
4437Q
2nd step
2nd step
4438Q