Specifications

V – 43
Function
Selector
No.
Setting and Specifications
1
|
3
No. 1 2 3
0 0 0 : -42.5 dBm (A)
0 0 1 : -44.0 dBm (B)
0 1 0 : -45.5 dBm (C)
0 1 1 : -47.0 dBm (D)
1 0 0 : -48.5 dBm (E)
1 0 1 : -50.0 dBm (F)
1 1 0 : -51.5 dBm (G)
1 1 1 : -53.0 dBm (H)
Detection threshold level for
voice signals inputted via the
network in the built-in TAD
operation
WSW33 (Function setting 11)
4
5
No. 4 5
0 0 : 14,400 bps
0 1 : 12,000 bps
1 0 : 9,600 bps
1 1 : 7,200 bps
Report output of polled trans-
mission requests
6 0: YES 1: NO
7
8
No. 7 8
0 0 : OFF
0 1 : Low (A)
1 0 : Medium (B)
1 1 : High (C)
Comfortable noise level
NOTE: The WSW33 is applicable to those models equipped with a built-in TAD.
Selectors 4 and 5: First communications speed choice for PCI (For those models equipped
with a built-in TAD)
These selectors are used to set the first communications speed choice with which the equip-
ment attempts to synchronize the data transmission via the PC interface. If the synchroniza-
tion fails, the equipment automatically steps down to the next lowest speed.
Selector 6: Report output of polled transmission requests
This function does not apply in the U.S.A. versions.
Selectors 7 and 8: Comfortable noise level
These selectors set the level of noise to be added during playing-back of voice signals re-
corded with no-signal compression.
If they are set to "0, 0," no noise will be added.
First communications speed
choice for PCI