Top cover ASSY (For LCD models)
(5) Disconnect the LCD flat cable from the panel PCB ASSY.
(6) Release the hooks A, and remove the panel PCB ASSY from the top cover ASSY.
Release the panel PCB flat cable from the each guide on the top cover ASSY.
(7) Remove the rubber key from the top cover ASSY.
(8) Release the hooks B, and remove the LCD cover from the top cover ASSY.
(9) Release the hook C, and remove the LCD from the LCD cover.
Fig. 3-18
Harness routing: Refer to “3. Bottom side of the top cover ASSY”.
Note:
After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
When connecting flat cables, do not insert them at an angle. After insertion, check
that the cables are not at an angle.
Panel PCB flat cable
Hook C
LCD
LCD cover
Hooks B
Rubber key
Panel PCB ASSY
Hooks A
Hooks A
Top cover ASSY
LCD flat cable
Guides