Error code 6A00
Detected discharge that may be attributable to dirty corona wire on the drum unit.
Electrodes location of the toner cartridge and drum unit
Fig. 2-5
Electrodes location of the machine
Fig. 2-6
Drum !
Slide the Green tab on Drum Unit.
<User Check>
Slide the green tab of the drum unit to left and right for two to three times to clean the
corona wire.
Clean the terminal of the drum unit.
Replace the drum unit.
Step Cause Remedy
1
Dirt on the high-voltage power
supply PCB terminal
Clean the electrodes of the machine.
2
High voltage electrodes
attachment failure
Check if the problem disappears after pressing
each electrode. If not, reattach the electrodes.
3
High-voltage power supply PCB
failure
Replace the high-voltage power supply PCB
ASSY.
4
Main PCB failure Replace the main PCB ASSY.