Barcode Print+ User's Guide
Table Of Contents
2 
Display with the stop pattern 
Display without the stop pattern 
2.2.5 Module size (“s”) 
Specifies the module size. 
ESC(s0p 
,,,v,,,b,,,s24850T123456789123 
1. Module height to width ratio (1–10, default: 3) 
2. Symbol length in the length to width ratio (default: 2) 
3. Symbol width in the length to width ratio (default: 3) 
4. Minimum module width (1–100, default: 10, unit: 1/100 of an inch) 
Example 
1,3,2,5s 
(Module: square; Symbol length: 1.5 x width; Module width: 0.05 in.) 
2.2.6 Barcode type (“T”) 
Specifies the barcode type. 
ESC(s0p 
,,,v,,,b,,,s24850T123456789123 
Value 
Code Type 
24850 
PDF417 
24855 
MacroPDF417 
2.2.7 Barcode data 
The actual user-defined information: 
ESC(s0p 
,,,v,,,b,,,s24850T123456789123 
ASCII control code characters (ASCII code 0–31) can be specified for PDF417 as follows: 
ESC 
&p#X 
<00> 
Where: 
#  is the number of control code characters 
<00>  is an example control code character 
Example 
To specify two ASCII code characters “0” and “1” with PDF417, use: 24850TESC&p2X<00><01>   