Instruction manual
Table Of Contents
- Go to Instruction Manual Top Page
- Cover-Top
- SAFETY INSTRUCTIONS
- CONTENTS
- 1. NAME OF EACH PART
- 2. SPECIFICATIONS
- 3. INSTALLATION
- 3-1. Power table
- 3-2. Installing the control box
- 3-3. Installing the rubber cushions
- 3-4. Installing the oil pan
- 3-5. Installing the cushions
- 3-6. Installing the switching plate
- 3-7. Installing the machine head
- 3-8. Installing the head rest
- 3-9. Installing the liquid cooling tank, optional
- 3-10.Installing the operation panel
- 3-11.Connecting the ground wire
- 3-12.Connecting the cords
- 3-13.Installing the belt cover
- 3-14.Installing the foot switch
- 3-15.Installing the spool stand
- 3-16.Installing the eye guard
- 4. LUBRICATION
- 5. OPERATION
- 6. CHECKING THE SEWING PATTERN
- 7. CORRECT USE
- 8. SEWING
- 9. MAINTENANCE AND INSPECTION
- 10. STANDARD ADJUSTMENTS
- 10-1.Adjusting the needle bar height
- 10-2.Adjusting the needle bar lift amount
- 10-3.Adjusting the driver needle guard
- 10-4.Adjusting the needle clearance
- 10-5.Adjusting the shuttle race thread guide
- 10-6.Adjusting the thread take-up amount
- 10-7.Adjusting the movable knife
- 10-8.Adjusting the work clamp lift amount
- 10-9.Work clamp pressure adjustment (KE-432B)
- 10-10. Work clamp closing-distance adjustment (KE-432B)
- 10-11. Work clamp interchangeability (KE-433B)
- 10-12. Adjusting the needle up stop position
- 10-13. Adjusting the thread wiper
- 10-14. Checking the input sensor and DIP switch input
- 10-15. Checking the input voltage
- 10-16. Clearing all memory settings
- 10-17. Moving stitch patterns
- 11. USING THE COUNTERS
- 12. CHANGING FUNCTIONS USING THE DIP SWITCHES
- 13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
- 14. TABLE OF ERROR CODES
- 15. GAUGE PARTS LIST ACCORDING TO SUBCLASSES
- 16. TROUBLESHOOTING
- 17. OPTIONAL PARTS
- Cover-Last
13
KE-430B, 431B, 432B, 433B
Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiv-
ing a serious electric shock, and problems with correct operation may also occur.
t
e
w
r
w
r
q
e
t
q
Table
Table
Red
White
Black
Yellow/Green
3-10.Installing the operation panel
1. Install the rear frame q to the work table (top or bottom) with the four wood screws w.
* At this time, tighten the wood screws w until the thickness of the rubber sheet is 2 to 2.5mm.
2. Install the front frame e to the rear frame q with the four screws r.
* The vertical orientation of the front frame e is the same whether it is installed to the top or the bottom
of the work table.
3. Insert the connector cord t into the control box through the hole at the side of the box. Refer to “3-12.
Connecting the cords” for details on connecting the cord.
4. Secure the connector cord t with the staples (in three places).
3-11.Connecting the ground wire
Connect to the power switch. However, the
black wire is insulated to the inside of the box
and is not used.
3. INSTALLATION
The operation panel can be installed to either the top or bottom of the work table.
Top of work table
Bottom of work table
Connect to ground
CAUTION
0062Q 0419Q
0418Q
Rubber sheet
2 - 2.5mm
0445Q