Instruction manual
Table Of Contents
- Go to Instruction Manual Top Page
- Cover-Top
- SAFETY INSTRUCTIONS
- CONTENTS
- 1. NAME OF EACH PART
- 2. SPECIFICATIONS
- 3. INSTALLATION
- 3-1. Power table
- 3-2. Installing the control box
- 3-3. Installing the rubber cushions
- 3-4. Installing the oil pan
- 3-5. Installing the cushions
- 3-6. Installing the switching plate
- 3-7. Installing the machine head
- 3-8. Installing the head rest
- 3-9. Installing the liquid cooling tank, optional
- 3-10.Installing the operation panel
- 3-11.Connecting the ground wire
- 3-12.Connecting the cords
- 3-13.Installing the belt cover
- 3-14.Installing the foot switch
- 3-15.Installing the spool stand
- 3-16.Installing the eye guard
- 4. LUBRICATION
- 5. OPERATION
- 6. CHECKING THE SEWING PATTERN
- 7. CORRECT USE
- 8. SEWING
- 9. MAINTENANCE AND INSPECTION
- 10. STANDARD ADJUSTMENTS
- 10-1.Adjusting the needle bar height
- 10-2.Adjusting the needle bar lift amount
- 10-3.Adjusting the driver needle guard
- 10-4.Adjusting the needle clearance
- 10-5.Adjusting the shuttle race thread guide
- 10-6.Adjusting the thread take-up amount
- 10-7.Adjusting the movable knife
- 10-8.Adjusting the work clamp lift amount
- 10-9.Work clamp pressure adjustment (KE-432B)
- 10-10. Work clamp closing-distance adjustment (KE-432B)
- 10-11. Work clamp interchangeability (KE-433B)
- 10-12. Adjusting the needle up stop position
- 10-13. Adjusting the thread wiper
- 10-14. Checking the input sensor and DIP switch input
- 10-15. Checking the input voltage
- 10-16. Clearing all memory settings
- 10-17. Moving stitch patterns
- 11. USING THE COUNTERS
- 12. CHANGING FUNCTIONS USING THE DIP SWITCHES
- 13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
- 14. TABLE OF ERROR CODES
- 15. GAUGE PARTS LIST ACCORDING TO SUBCLASSES
- 16. TROUBLESHOOTING
- 17. OPTIONAL PARTS
- Cover-Last
KE-430B, 431B, 432B, 433B
40
1. When the X-SCALE indicator q is illuminated and the RESET switch e is pressed while the TEST switch w
is being pressed, the state of the X home position signal will appear on the display window r.
· When sensor is ON · When sensor is OFF
2. Each time the SELECT switch t is pressed, a different indicator will illuminate and the operating condition
for the corresponding item will appear on the display window r.
· When X-SCALE indicator is illuminated...... X home position sensor (ON when home position detected)
· When Y-SCALE indicator is illuminated ...... Y home position sensor (ON when home position detected)
· When SPEED indicator is illuminated ......... Synchronizer ( * 1)
· When COUNTER indicator is illuminated ... Presser sensor (ON when presser is lowered)
·
When PROGRAM NO. indicator is illuminated ...
Work clamp closed sensor (ON when work clamp is open
[KE-432B only])
*1 The synchronizer display simultaneously displays the needle up signal (3rd digit), the 24-section signal
(2nd digit) and the needle down signal (1st digit).
[ H L L] “H” when the sensor is on, and “L” when the sensor is off
Needle down signal
24-section signal
Needle up signal
If the DIP switches at the side of the operation panel are changed at this time, the number of the DIP switch
which was changed will be displayed in the 4th digit position of the display window r for about one
second.
NOTE:
The DIP switch can be changed at this time without turning off the power so that you can check the DIP switch input.
However, you should normally always turn off the power when changing DIP switch settings.
3. Press the TEST switch w again to return the display to the normal condition.
SELECT
PROGRAM NO.
RESET
COUNTER
X
-
SCALE
Y
-
SCALE
SPEED
P
TEST
BOBBIN.WIND
P4P3
P1 P2
POWER
e
w
t
r
q
10-14. Checking the input sensor and DIP switch input