Instruction manual
Table Of Contents
- Go to Instruction Manual Top Page
- Cover-Top
- SAFETY INSTRUCTIONS
- CONTENTS
- 1. NAME OF EACH PART
- 2. SPECIFICATIONS
- 3. INSTALLATION
- 3-1. Power table
- 3-2. Installing the control box
- 3-3. Installing the rubber cushions
- 3-4. Installing the oil pan
- 3-5. Installing the cushions
- 3-6. Installing the switching plate
- 3-7. Installing the machine head
- 3-8. Installing the head rest
- 3-9. Installing the liquid cooling tank, optional
- 3-10.Installing the operation panel
- 3-11.Connecting the ground wire
- 3-12.Connecting the cords
- 3-13.Installing the belt cover
- 3-14.Installing the foot switch
- 3-15.Installing the spool stand
- 3-16.Installing the eye guard
- 4. LUBRICATION
- 5. OPERATION
- 6. CHECKING THE SEWING PATTERN
- 7. CORRECT USE
- 8. SEWING
- 9. MAINTENANCE AND INSPECTION
- 10. STANDARD ADJUSTMENTS
- 10-1.Adjusting the needle bar height
- 10-2.Adjusting the needle bar lift amount
- 10-3.Adjusting the driver needle guard
- 10-4.Adjusting the needle clearance
- 10-5.Adjusting the shuttle race thread guide
- 10-6.Adjusting the thread take-up amount
- 10-7.Adjusting the movable knife
- 10-8.Adjusting the work clamp lift amount
- 10-9.Work clamp pressure adjustment (KE-432B)
- 10-10. Work clamp closing-distance adjustment (KE-432B)
- 10-11. Work clamp interchangeability (KE-433B)
- 10-12. Adjusting the needle up stop position
- 10-13. Adjusting the thread wiper
- 10-14. Checking the input sensor and DIP switch input
- 10-15. Checking the input voltage
- 10-16. Clearing all memory settings
- 10-17. Moving stitch patterns
- 11. USING THE COUNTERS
- 12. CHANGING FUNCTIONS USING THE DIP SWITCHES
- 13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
- 14. TABLE OF ERROR CODES
- 15. GAUGE PARTS LIST ACCORDING TO SUBCLASSES
- 16. TROUBLESHOOTING
- 17. OPTIONAL PARTS
- Cover-Last
KE-430B, 431B, 432B, 433B
41
10. STANDARD ADJUSTMENTS
SELECT
PROGRAM NO.
RESET
COUNTER
X
-
SCALE
Y
-
SCALE
SPEED
P
TEST
BOBBIN.WIND
P4P3
P1 P2
POWER
r
e
t
200V
220V
230V
100V
380V
400V
415V
Display
[090 - 110]
[100 - 120]
[105 - 125]
[100 - 120]
Notes
“100” is displayed when the input voltage is 200 V.
“110” is displayed when the input voltage is
100V (for 100-V spece.), 380V (for 380-V spece.),
400V (for 400-V spece.)or 415V (for 415-V spece.).
Specifications
w
q
10-15. Checking the input voltage
1. Turn on the power switch.
2. Press the SELECT switch q until the Y-SCALE indicator w illuminates.
3. While pressing the TEST switch e, press the RESET switch r.
4. If the input voltage is normal, the input voltage conditions will be shown in the display window t as
indicated in the table above.
5. Press the TEST switch e again to return the display to the normal condition.
10-16. Clearing all memory settings
If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have
been made by means of the memory switch, for instance. In such cases, carry out the following procedure to
clear the memory, and also check the DIP switch settings.
[ Method ]
While pressing the RESET switch, turn on the power. This will clear all of the memory setting.
NOTE
• This operation causes all settings stored in memory such as memory switch and user program settings to be cleared.
• If the optional emergency stop switch has been installed, you should reset memory switch No. 10 to ON.
0582Q