Instruction manual
Table Of Contents
- Go to Instruction Manual Top Page
- Cover-Top
- SAFETY INSTRUCTIONS
- CONTENTS
- 1. NAME OF EACH PART
- 2. SPECIFICATIONS
- 3. INSTALLATION
- 3-1. Power table
- 3-2. Installing the control box
- 3-3. Installing the rubber cushions
- 3-4. Installing the oil pan
- 3-5. Installing the cushions
- 3-6. Installing the switching plate
- 3-7. Installing the machine head
- 3-8. Installing the head rest
- 3-9. Installing the liquid cooling tank, optional
- 3-10.Installing the operation panel
- 3-11.Connecting the ground wire
- 3-12.Connecting the cords
- 3-13.Installing the belt cover
- 3-14.Installing the foot switch
- 3-15.Installing the spool stand
- 3-16.Installing the eye guard
- 4. LUBRICATION
- 5. OPERATION
- 6. CHECKING THE SEWING PATTERN
- 7. CORRECT USE
- 8. SEWING
- 9. MAINTENANCE AND INSPECTION
- 10. STANDARD ADJUSTMENTS
- 10-1.Adjusting the needle bar height
- 10-2.Adjusting the needle bar lift amount
- 10-3.Adjusting the driver needle guard
- 10-4.Adjusting the needle clearance
- 10-5.Adjusting the shuttle race thread guide
- 10-6.Adjusting the thread take-up amount
- 10-7.Adjusting the movable knife
- 10-8.Adjusting the work clamp lift amount
- 10-9.Work clamp pressure adjustment (KE-432B)
- 10-10. Work clamp closing-distance adjustment (KE-432B)
- 10-11. Work clamp interchangeability (KE-433B)
- 10-12. Adjusting the needle up stop position
- 10-13. Adjusting the thread wiper
- 10-14. Checking the input sensor and DIP switch input
- 10-15. Checking the input voltage
- 10-16. Clearing all memory settings
- 10-17. Moving stitch patterns
- 11. USING THE COUNTERS
- 12. CHANGING FUNCTIONS USING THE DIP SWITCHES
- 13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
- 14. TABLE OF ERROR CODES
- 15. GAUGE PARTS LIST ACCORDING TO SUBCLASSES
- 16. TROUBLESHOOTING
- 17. OPTIONAL PARTS
- Cover-Last
KE-430B, 431B, 432B, 433B
47
Clearing the user programs
2. Depress the foot switch to the second step.
3. Check the sewing pattern (see P.22), and then sew the pattern selected.
1. Switch the machine to recording mode by the procedure in steps 2. of recording a user program.
2. Use the DISPLAY SET switches !0 to specify the user program number which is to be cleared of data.
Using a user program
12. CHANGING FUNCTIONS USING THE DIP SWITCHES
* P1 to P4 can be selected using the P1 to P4 user program switches !1. P5 to P15 can be selected by pressing
the P1 to P4 switches together in various combinations as shown below.
(P5 to P15 functions are valid if the main PROM version is “MN-F” or later.)
The switches with solid lines are valid switches for selection.
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
P4P3
P1 P2
To select P5 To select P6 To select P7 To select P8 To select P9 To select P10
To select P11 To select P12 To select P13 To select P14 To select P15
0472Q
3. Press the RESET switch !2.
* The buzzer will sound and the user program with the number selected will be cleared.
* If you press and hold the RESET switch !2 until after the buzzer has sounded twice, all user programs
will be cleared.
NOTE:
If data has been recorded in user programs P1, P2, P3 and P4 and you then clear the data in user program P2, the
contents of P3 will be transferred to P2, and the contents of P4 will be transferred to P3.
1. Press the DISPLAY SET switches !0 to select the speed program number for the user program that you
would like to use.
*The user program except P16 can also be selected using the user program switches !1. (See below.)