ESC iXD2 Specify delimiter
ASCII: ESC i X D 2 n1 n2 data
Decimal: 27 105 88 68 50 nd1 nd2 datad
Hexadecimal: 1B 69 58 44 32 nh1 nh2 datah
Parameters
01h≤nh1≤14h
nh2: 00h (Fixed)
00h≤datah≤FFh
Description
The delimiter is used to indicate when to move to the next object in data that is being sent.
Specifies the text string for the delimiter.
nh1+(nh2*256):
Length of the text string (between 1 and 20)
data:
Text string (The maximum number of characters that can be set is 20 characters
(bytes).)
The default text string for the delimiter is “09h” (Tab code).
This command is a static command.
Remarks
Invalid if more than 20 characters have been specified
Example
To change the delimiter to “,” (2Ch):
Since the text string contains one character, nh1=01h and nh2=00h. In addition, with the text string (datah)
“,” (2Ch), the command will be as follows.
ESC i X D 2 01h 00h 2Ch