P-touch Template Manual/ Command Reference

Table Of Contents
P-touch Template Command Reference
- 69 -
7. Control Command Details
ESC iXh2 Specify rotated print
ASCII: ESC i X h 2 n1 n2 n3
Decimal: 27 105 88 104 50 nd1 nd2 nd3
Hexadecimal: 1B 69 58 68 32 nh1 nh2 nh3
Parameters
nh1: 01h (Fixed)
nh2: 00h (Fixed)
nh3: 00h, 01h
Description
Select rotate setting.
nh3=00h:
No rotation
nh3=01h:
180 degrees rotation
The default value for the rotate setting is "00h" (No rotaion).
This command is a static command.
Example
To set the rotate setting to 180 degrees rotation:
Since nh3=01h, the command will be as follows.
ESC i X h 2 01h 00h 01h
(1Bh 69h 58h 68h 32h 01h 00h 01h)