Chapter 3 Programming with Command Function
Setting the option output
This is set to flip/flop the option output.
Command to be used
L
7
7 1
Flipping/flopping option output 1
L
7
7 2
Flipping/flopping option output 2
L
7
7 3
Flipping/flopping option output 3
L
7
7 0
Canceling option output setting
1. Move the needle to the desired position.
2. Input the command for option output.
Ending programming
When programming is completed, input an end code.
Command to be used
E
1
1 1
Normal end
E
1
1 2
Fixing the sewing speed at 1000 spm or lower.
E
1
1 3
Not carrying out thread removal.
E
1
1 4
Setting the sewing speed at 1000 spm or lower without
thread removal.
E
1
1 5
Carrying out no thread breakage.
E
1
1 0
Fixing the sewing speed at 1500 spm or lower.
1. When the data is created, input the end code.