SDS

SAFETY DATA SHEET
Page : 3 / 8
Revision nr : 1.0
Issue date : 11/18/2019
Multi surface floor cleaner
Supersedes :
6.3. Methods and material for containment and cleaning up
Methods for cleaning up
:
Stop leak if safe to do so. Dam up the liquid spill. Small quantities of liquid spill: take
up in non-combustible absorbent material and shovel into container for disposal.
Recover large spills by pumping (use an explosion proof or hand pump). Place in a
suitable container for disposal in accordance with the waste regulations (see Section
13). This material and its container must be disposed of in a safe way, and as per
local legislation.
6.4. Reference to other sections
Concerning personal protective equipment to use, see item 8. Concerning disposal elimination after cleaning, see item 13.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Precautions for safe handling
:
Provide adequate ventilation. Use personal protective equipment as required.
Concerning personal protective equipment to use, see item 8. Do not breathe
vapors. Avoid contact with skin, eyes and clothing. Take any precaution to avoid
mixing with Incompatible materials, Refer to Section 10 on Incompatible Materials.
Ensure proper process control to avoid excess waste discharge (temperature,
concentration, pH, time). Avoid release to the environment.
Hygiene measures
:
Keep good industrial hygiene. Wash hands and other exposed areas with mild soap
and water before eating, drinking or smoking and when leaving work. Do not eat,
drink or smoke when using this product. Keep away from food, drink and animal
feedingstuffs. Remove contaminated clothes. Separate working clothes from town
clothes. Launder separately. Wash contaminated clothing before reuse.
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions
:
Store in a dry, cool and well-ventilated place. Do not store near or with any of the
incompatible materials listed in section 10. Bund storage facilities to prevent soil and
water pollution in the event of spillage.
Packaging materials
:
Keep only in the original container. Suitable material: Unsuitable material:
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Monitoring methods
Personal air monitoring,Room air monitoring
Additional information
:
Personal air monitoring :
Room air monitoring
Recommended monitoring procedures
8.2. Exposure controls
Engineering measure(s)
:
Provide adequate ventilation. Organizational measures to prevent /limit releases,
dispersion and exposure. Safe handling: see section 7 .
Personal protective equipment
:
The type of protective equipment must be selected according to the concentration
and amount of the dangerous substance at the specific workplace.
Hand protection
:
Wear chemically resistant gloves. Suitable material: Nitrile rubber, natural rubber
gloves (>0.3mm, BTT: 8h). The quality of the protective gloves resistant to chemicals
must be chosen as a function of the specific working place concentration and
quantity of hazardous substances.
Eye protection
:
Use suitable eye protection. (EN166):
Body protection
:
Wear suitable protective clothing.