Operating instructions

General Information and Specification
OPERATING LIMITS - ALL
MODELS
AC Mode: 132 VAC Max., 108
VAC Min.
15.4 VDC Max., 10.5
VDC Min.
DC Mode: 15.4 VDC Max., 11.5
VDC Min.
Gas Mode: 11" W.C. Gas Supply
10.5" W.C. Min. Burner
Pressure (High Fire)
15.4 VDC Max., 10.5
VDC Min.
MODELS 442, 443
RATINGS
1050 Btu/Hr Input
LP Gas Mode:
11" W.C. Gas Supply
LP14 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 200 Watts
DC Mode (3-Way only):
12 Volts DC
MODELS 452, 453
RATINGS
1200 Btu/Hr Input
LP Gas Mode:
11" W.C. Gas Supply
LP14 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 200 Watts
DC Mode (3-Way only):
12 Volts DC
MODELS 462, 463
RATINGS
1450 Btu/Hr Input
LP Gas Mode:
11" W.C. Gas Supply
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
MODELS 482, 483
RATINGS
1500 Btu/Hr Input
LP Gas Mode:
11" W.C. Gas Supply
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
CURRENT DRAWS - 442, 443, 452, 453
Relighter - 30 milliamps
AC Heating Element - 1.5 amps at 110 Volts AC
1.7 amps at 120 Volts AC
DC Heating Element - 9.2 amps at 12 Volts DC
10.7 amps at 14 Volts DC
CURRENT DRAWS - 462, 463, 482, 483
Relighter - 30 milliamps
Humidity Heater - 240 milliamps or .24 amps
Interior Lamp (when door open) - 600 milliamps or .60 amps
AC Heating Element - 2.7 amps at 110 Volts AC
2.9 amps at 120 Volts AC
DC Heating Element - 13.8 amps at 12 Volts DC
16.1 amps at 14 Volts DC
B101
3-2