3. Installation Locations
When wall mounting, place out of reach of children. Under no
circumstances should children be allowed to handle the CO alarm.
Placing the alarm at eye level allows for optimum monitoring of the
digital display.
Locations To Avoid
IMPORTANT: Improper location can affect the sensitive electronic
components in this alarm. To avoid causing damage to the unit, to
provide optimum performance, and to prevent unnecessary nuisance
alarms:
Do not install in kitchens, garages or furnace rooms that may expose
the sensor to substances that could damage or contaminate it.
Do not install in areas where the temperature is colder than 4.4°C
(40°F) or hotter than 37.8°C (100°F) such as crawl spaces, attics,
porches and garages.
• Do not install within 5 ft. of heating or cooking appliances. (Kidde
recommends 15 ft. to prevent nuisance alarms).
• Do not install near vents, flues, chimneys or any forced/unforced air
ventilation openings.
Do not install near ceiling fans, doors, windows or areas directly
exposed to the weather.
Do not install in dead air spaces, such as peaks of vaulted ceilings or
gabled roofs, where CO may not reach the sensor in time to provide
early warning.
Do not install this unit near deep-cell large batteries. Large batteries
have emissions that can cause the alarm to perform at less than
optimum performance.
Do not obstruct the vents located on the alarm. Do not place the
alarm where drapes, furniture or other objects block the flow of air to
the vents.
Do not install on a switched or dimmer-controlled outlet.