User's Manual

100
From here you would include the External ID, if the results were being exported to a FAT file for
synchronization with the employer’s computer system. Include the standards for the particular test
in the white box (in this example it is “0”).
Next you are required to select the comparison method for the standard you entered. The
following are the options available:
Compare the score for each column with the standard for that column
Compare the left hand score with the standard for the left hand, and compare the right hand
score with the standard for the right hand
Compared the combined maximum of the right and left hand scores with the left hand standard
Compare the hand that scored the higher of the two hands with the higher of the two standards.
Compare the hand that scored the lower of the two hands with the lower of the two standards
Compare the dominant hand score with the higher of the two standards. Compare the non-
dominant hand score with the lower of the two standards
Then select from the drop down menu whether “The evaluee must fail all or only one of the
standards defined above to fail this individual test.”
Once set up, select the next test from the drop down menu to be included in the Post Offer of
Employment Test and set up the standard. Continue until all the standards have been set up for
this particular employer.
POET Standards Report
Once completed click on Print from the Set Standards screen or select POET Standards Report
from the POET drop down menu from the main screen of ODES.