Arrange the MTM Panels on the floor in the proper sequence. The order is as follows (from left to right):
Panel 6, 1, 2, 3, 4, and 5.
Place the top and bottom brackets so that the middle four MTM panels can be attached. You may want
to move panel 6 and 5 aside for the time being. Panels 1-4 need to be attached using the 5/32 Allen
Key, the 1 ΒΌ screws and the washers. Attach the top bracket to the panels prior to attaching the bottom
bracket.
Once the top and bottom brackets have been attached, you are now ready to attach panel 5 and 6. This
should be done one panel at a time, starting with panel 6 on the left. Screw one bolt into the top bracket
and one bolt into the bottom bracket in order to line up the panel with the bracket. You may then attach
the second set of bolts in order to set the panel in place. Repeat this procedure for panel 5 on the right
hand side.