User's Manual

Table Of Contents
mBSC-H DAS System
Installation Manual Issue 7
© 2009-2014, BTI Wireless Page 29
4.2.5 Electrical Installation
4.2.5.1 Electrical Safety Precautions
Please read the general Safety Precautions presented in Section 1.2 Safety Precautions
1. This Unit uses high voltages. Follow the instructions for installation provided in this
manual to prevent serious accidents including loss of life, severe personal injury or
extensive property damage.
2. The Unit must be grounded before connecting any power supply. Grounding is a
required precautionary measure. Grounding instructions are provided and should be
followed for safety.
3. The Unit is internally protected against over-voltage, but in areas with strong and frequent
lightning strikes additional lightning protection is strongly recommended. Grounding the
antenna cables close to the antenna connectors will help prevent damage from atmospheric
discharge.
4. Verify that there is a suitable circuit breaker and an over-current limiting device connected
between the mains and the Remote Unit.
5. Check that the mains supply is disconnected, before connecting or disconnecting the main
power connector at the Remote Unit.
6. An easily reached emergency disconnect device should be provided in the mains circuit if the
power feeds to the Remote Unit(s) are not within close reach.
7. The Remote Unit should be installed in close proximity to a power source with a circuit
breaker to ensure safe installation and for ease of power connectivity.
8. Electrical and electronic components can be destroyed by incorrectly wired connections.
9. Cable connector materials must meet manufacturer specifications to avoid corrosion at the
connectors.
10. Check cable connections to ensure that water cannot penetrate the Unit.
11. Caution should be used when attaching the antenna. Hand tightening should be sufficient for
connecting the antenna during installation. Manufacturer's recommendation for torque
specification should be used during installation. Use the appropriate tool to complete the
Antenna installation, but do not use tools, such as pliers, as they may cause damage to the
Remote Unit.
12. A voltage limiting device is strongly recommended for electrical networks that often produce
spikes.
13. Compliance with the surge requirement of EN 61000-4-5 (fine protection) has been met by this
Unit. Installing additional external surge protection, depending on the individual application,
via local supply connection and/or coarse protection is recommended to avoid damage
caused by electrical surges.