User's Manual

Table Of Contents
mBSC-H DAS System
Installation Manual Issue 7
© 2009-2014, BTI Wireless Page 31
Warning: Do not look into the end of the fiber optic cable. Do not look directly into the optical
transmitter of any Unit or exposure to laser radiation may result. An optical power meter
should be used to check the active fibers.
Use the following procedure to connect the fiber optic cable:
1. Connect or splice the drop Fiber cable to the outside plant cable. Verify that there is sufficient cable
length to reach from the splice enclosure or fiber access terminal (not provided) to the bottom of the
Master Remote Unit
2. Route the free end of the drop cable to the enclosure through the junction box as shown in Figure 4-13.
3. Leave sufficient slack to allow the cable to be connected and disconnected from the enclosure fiber
optic port without bending or crimping the fiber optic cable.
4. Remove the cap from the interface port labeled "FIBER". Connect the fiber optic cable to the port on the
bottom of the enclosure.
Figure 4-13. Junction Box
4.2.5.5 Antenna Cable Connection
The antenna feed line(s) must be routed from the antenna to each Remote Unit. The cable must have the
appropriate antenna connector termination to connect to the RU antenna port (ANT), shown in Figure
4-14.
Figure 4-14. Antenna port
Use the following procedure to install the antenna cable: