Connect the other end of the RF cable to the port labeled “TX_IN” on the SLAVE Remote Unit User
Interface as shown in Figure 4-17.
Connect the second cable to the port labeled "RX_IN" on the MASTER RU.
Connect the other end of the second RF cable to the port labeled "RX_OUT on the SLAVE RU.
Figure 4-17. RF cable connection between Master and Slave Remote Unit
1 Slave to Slave Connection: Connect an RF cable into the port labeled "TX_OUT" on the first SLAVE
RU User interface.
2 Connect the other end of the RF cable to the port labeled "TX_IN" on the next SLAVE RU Unit.
Continue connecting all SLAVE RUs in this manner, as shown in Figure 4-18.
3 Connect an RF cable into the port labeled "RX_OUT" on the first SLAVE RU.
4 Connect the other end of the RF cable to the port labeled "RX_IN" on the next SLAVE RU. Continue
connecting all SLAVE RUs in this manner.
5 Power may now be applied to all Master and Slave Units used in this configuration.