4.3.4.2 Grounding
The Unit must be grounded. The Host Unit is grounded during a factory installation in the optional
cabinet with an earth-bonding cable connected to the provided grounding connection. Do not
connect external devices to the grounding connection.
Please verify the Unit is securely grounded. If it is no longer securely grounded, please use the following
procedure to ground the Unit:
Figure 4-20. Host Unit Grounding Connection
1. Find the screw at the bottom right corner of the Host Unit as shown in Figure 4-20.
2. Loosen the screw located on the grounding connection.
3. Connect the cabinet mounted earth-bonding cable between the two lock and flat washers as shown in
Figure 4-21. Ensure the grounding surface is clean and free of paint, insulating material or
contaminants.