Installation Manual Issue 7
© 2009-2014, BTI Wireless Page 44
Figure 4-22. Factory Installed DC Power Cable
1. Confirm electrical polarity of the power cables to match the customer provided DC power system.
2. Verify the DC power cable is attached securely, as shown Figure 4-22.
3. If the DC power cable is not secure, turn off all associated DC power to the Host Unit, and secure the
power cables as shown.
4.3.4.4 Install the BIU and FIU modules
Figure 4-23. BIU and FIU modules
1. Remove the blank module covers for the chosen module slot locations.
2. Slide the BIU and FIU modules in to each separate designated module slot, Figure 4-23.
3. Secure the screws at the top and bottom of each module.
4.3.4.5 Alarm Installation
The Alarm interface is an optional customer centered configuration.
The Alarm Input configuration gives the user the means to monitor third party alarms, such as battery or
intrusion alarms.
The Alarm Output configuration provides the customer with the means to monitor major or minor alarms
via Form C relay.
The alarm interface is located at the back of the Host Unit as shown in Figure 4-24.