User's Manual

Table Of Contents
mBSC-H DAS System
Installation Manual Issue 7
© 2009-2014, BTI Wireless Page 48
4.3.4.8 Connect POI to BIU
The Point of Interface (POI) is an optional component. The POI is connected to the BIU, Figure 4-29,
using the following procedure:
1. Connect one end of a POI interface cable into the BIU port labeled "Tx1 In".
2. Connect the other end of the cable to the POI port labeled "Tx-L".
3. Connect the one end of a POI interface cable into the BIU port labeled "Rx4 Out".
4. Finally, connect the other end of the cable to the POI port labeled "Rx-L".
Figure 4-29. POI to BIU Connection
4.3.4.9 Connect the Fiber Optic Cable
The Fiber optic cable is connected to the FIU module by attaching the cable to the port labeled "Fiber-1" as
shown in Figure 4-30.
Figure 4-30. Fiber Optic Cable Connection to the FIU Module
4.3.5 Host Unit Installation Review
4.3.5.1 Electrical Installation Review