5.2.6 Connect Host Unit to Server
With the IP address updated, the Host Unit must be connected the server, Figure 5-19, for communication
information to function. The Host Unit is connected from the Network port on the back interface through the
hub to the server as shown in Figure 5-20 or may be directly connected from the back interface port to the
server. The Host Unit may also be connected to the server from the RCU network port on the front
interface, either directly or through the hub to the server. Only one network port connection may be used at
a time.
Figure 19. Connect Host Unit to Server
Only one port may be connected to the server at a time, as both front interface and back
interface network ports are the same port.
Figure 5-20. HU Back Interface Network Connection
5.3 MANAGING AND MONITORING ALARMS
5.3.1 Alarm Manager
The NMS is also the means for managing and monitoring the DAS systems through the Alarm Manager(A)
menu or the Alarm Icon on the Menu bar. The managing and monitoring of the DAS system is more
completely detailed in the BTI NMS User Manual.