Installation Manual Issue 7
© 2009-2014, BTI Wireless Page 94
component of the Host Unit requires replacement, care must be taken with modules so that seals are not
damaged unintentionally as this may void warranty.
Please see the Replacement Parts List for specific components available.
6.3 NMS
The NMS may require periodic updates, both Firmware and Software. Please see Sections 4.4.7 Firmware
Updates and 4.4.8 Software Upgrade Installation.
6.4 REMOTE UNITS
It is important to note that preventative maintenance is not required for the Remote Unit.
Danger: Disconnect the Remote Unit from the mains prior to any maintenance.
NOTE: It is important to note that preventative maintenance is not required for the
Remote Unit.
6.4.1 Fans
Visually inspect fan units at intervals based upon the location, corresponding environment and pollution
levels. Maintenance is not required for the fan units, but the fan units may be cleaned, if needed using any
commercially available small compressed air device (max. 5 bar).
Once an RU has been powered up for the first time, the fans rotate at full speed. After one minute, the fan
speed will decrease to 75% and after another minute, the fan speed decreases to 25% and will then stay at
25% until the RU reaches its normal operating temperature.
In a normal operating situation, the fans are generally operating at approximately 50% of their power, this
helps prevent dust and other contaminants from settling on the fan blades and the cooling fins. A fan alarm
will be generated should the fan current drop below its normal operating fan speed. Please see the
Replacement Parts list should a replacement fan unit be required and follow any replacement instructions
provided by the manufacturer.