User's Manual
Table Of Contents
- Document History
- Revision History
- GENERAL SAFETY PRECAUTIONS
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- 1 Introduction
- Figure 1Block Diagram of Host Unit
- Figure 2 Block Diagram of Remote Node
- 2 Safety
- 3 System Overview and Unit Description
- Figure 3mBSC System Functional Overview
- Figure 4 Host Unit
- Figure 5BIU
- Figure 6FIU
- Figure 7 PSU
- Figure 8RCU
- Table 1 Host Unit User Interface
- Front Panel
- Rear Panel
- Figure 10Fiber CM-BTS/ANT Enclosure Outline
- Figure 11Fiber CM-BTS/ANT Interior Layout
- Table 6Fiber CM-BTS/ANT Enclosure User Interface
- Figure 12Fiber CM-BTS/ANT Enclosure User Interface
- Table 7Single-band BDA Enclosure User Interface
- Figure 14 Single-band RU Enclosure User Interface
- Table 8 Indicator Description
- Table 9Shroud Specification
- 4 System Installation
- Figure 17 Mounting Brackets for 19” Rack Installation
- Figure 18Host Unit-19” Rack Mounting View
- Figure 19Host Unit Grounding Stud
- Figure 20 Grounded Host Unit
- Figure 21 BTS QMA Coaxial Cable Connection
- Figure 23E2000 Fiber Optic Port on Host Unit FIU
- Figure 2448VDC Host Power Connection
- Figure 25IP Connection for local GUI Control
- Figure 26Modem Port on RCU (DB9 male)
- Figure 27 Mounting Panel Mounting
- Figure 28Mount the Remote Unit on the Mounting Panel
- Figure 30Grounding Stud
- Figure 31 Grounding Wire the Ring Terminal
- SMA Coaxial Cable Inter-connection on Fiber CM-BTS/ANT Enclosure
- SMA Coaxial Cable Inter-connection on Single-band Enclosure
- DIN(7/16) Coaxial Cable Inter-connection on Single-band RU Enclosure
- N Type Coaxial Cable Inter-connection on CM-ANT Enclosure
- Figure 34Fiber Optic Cable Connection to Fiber CM-BTS Enclosure
- Warning
- Figure 35 AC Power Junction Box
- Figure 364-Pin AC Power Connector
- Figure 39 Flow Chart of System Debugging
- 5 System Monitoring &Configuration
- Figure 40– EMS Local GUI Login
- Figure 41- Main Page Expanded Topology
- Figure 42- Main Page Summary View
- Figure 43- RCU Component View
- Figure 44- Main Page Equipment Status
- Figure 45- FIU Optical Power Levels
- Figure 46- CM Optical Power Levels
- Table 15System Alarms
- 6 Maintenance
- Figure 56Host Unit Trouble Shooting
- Figure 57Remote Unit Trouble Shooting
- 7 Terms, Acronyms & Abbreviations
- IC Radiation Exposure Statement
- IC Déclaration sur la radio exposition
MBSC0800-040-RU
MBSC0800-040-RU July 02, 2014
Page 23
4 System Installation
4.1 Unpacking and Inspection
Every mBSC-C component has been tested and calibrated at the factory. Unpack the mBSC-C components
carefully after they arrive at the installation site. Open the wooden container and remove the foam padding.
If the equipment is damaged:
Immediately contact the transportation and notify them of the damage.
A claim should be filed with the carrier once the extent of any damage is assessed.
If possible, always inspect the equipment in the presence of the delivery person.
If the equipment is damaged and must be returned to BTI’s nearest RMA facility:
Log on the BTI website, or call 714-230-8333for a return authorization.
BTI will not accept returns without a RMA number.
Claims for loss or damage may not be withheld from BTI, nor may any payment due be with held pending
the outcome thereof.
BTI CANNOT be held responsible for the freight carrier’s performance.
4.2 Installation Preparation
4.2.1 Required Tools
The following equipment and tools may be required for a successful installation:
Multi-meter
Phillips screwdrivers
Flat blade screwdrivers
Wrenches
Drill
VSWR testing device
N adapters
RF testing cables
RF Power meter (part of hand-held tester)
4.2.2 Installation Location
The mBSC Host unit is typically installed within a 19” rack: