User's Manual
Table Of Contents
- Document History
- Revision History
- GENERAL SAFETY PRECAUTIONS
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- 1 Introduction
- Figure 1Block Diagram of Host Unit
- Figure 2 Block Diagram of Remote Node
- 2 Safety
- 3 System Overview and Unit Description
- Figure 3mBSC System Functional Overview
- Figure 4 Host Unit
- Figure 5BIU
- Figure 6FIU
- Figure 7 PSU
- Figure 8RCU
- Table 1 Host Unit User Interface
- Front Panel
- Rear Panel
- Figure 10Fiber CM-BTS/ANT Enclosure Outline
- Figure 11Fiber CM-BTS/ANT Interior Layout
- Table 6Fiber CM-BTS/ANT Enclosure User Interface
- Figure 12Fiber CM-BTS/ANT Enclosure User Interface
- Table 7Single-band BDA Enclosure User Interface
- Figure 14 Single-band RU Enclosure User Interface
- Table 8 Indicator Description
- Table 9Shroud Specification
- 4 System Installation
- Figure 17 Mounting Brackets for 19” Rack Installation
- Figure 18Host Unit-19” Rack Mounting View
- Figure 19Host Unit Grounding Stud
- Figure 20 Grounded Host Unit
- Figure 21 BTS QMA Coaxial Cable Connection
- Figure 23E2000 Fiber Optic Port on Host Unit FIU
- Figure 2448VDC Host Power Connection
- Figure 25IP Connection for local GUI Control
- Figure 26Modem Port on RCU (DB9 male)
- Figure 27 Mounting Panel Mounting
- Figure 28Mount the Remote Unit on the Mounting Panel
- Figure 30Grounding Stud
- Figure 31 Grounding Wire the Ring Terminal
- SMA Coaxial Cable Inter-connection on Fiber CM-BTS/ANT Enclosure
- SMA Coaxial Cable Inter-connection on Single-band Enclosure
- DIN(7/16) Coaxial Cable Inter-connection on Single-band RU Enclosure
- N Type Coaxial Cable Inter-connection on CM-ANT Enclosure
- Figure 34Fiber Optic Cable Connection to Fiber CM-BTS Enclosure
- Warning
- Figure 35 AC Power Junction Box
- Figure 364-Pin AC Power Connector
- Figure 39 Flow Chart of System Debugging
- 5 System Monitoring &Configuration
- Figure 40– EMS Local GUI Login
- Figure 41- Main Page Expanded Topology
- Figure 42- Main Page Summary View
- Figure 43- RCU Component View
- Figure 44- Main Page Equipment Status
- Figure 45- FIU Optical Power Levels
- Figure 46- CM Optical Power Levels
- Table 15System Alarms
- 6 Maintenance
- Figure 56Host Unit Trouble Shooting
- Figure 57Remote Unit Trouble Shooting
- 7 Terms, Acronyms & Abbreviations
- IC Radiation Exposure Statement
- IC Déclaration sur la radio exposition
MBSC0800-040-RU
MBSC0800-040-RU July 02, 2014
Page 31
1) Follow the procedures provided by the manufacturer when installing the remote unit. Do not install the unit in a place or in
a manner that does not meet the manufacturer’s specifications.
2) Use the mounting hardware supplied by the manufacturer. If non-standard mounting hardware is used it must meet the
requirements for mounting the unit as specified by the manufacturer.
3) Safety measures for lifting heavy materials should be followed to prvent injury.
NOTE: It is important that specified load limits for the unit are not exceeded as this may void the warranty.
4) High temperatures may occur due to power dissipation. Please follow the specifivations for proper remote unit ventilation
as indicated by the manufacturer.
5) Check that the mains supply is diconnected, before connecting or disconnecting the main power connector at the remote
unit.
6) Do not block airflow ventilation outlets during installation or remote unit(s) may sustain critical damage.
4.4.1.1 Install the Mounting Panel
Follow the procedure below to install the mounting panel on the wall:
1. Mark the mounting panel fixing holes position on the wall.
2. Drill the holes (Ф10) on the wall.
3. Install the concrete anchors and tighten it firmly.
4. Hold the panel in the proper direction.
5. Secure the panel by using M8x70 (6pcs) expansion bolts
Bracket Mounting
Installing Inflatable Bolt
Figure 27 Mounting Panel Mounting