User's Manual

Table Of Contents
MBSC0800-040-RU
MBSC0800-040-RU July 02, 2014
Page 41
4.5.3 mBSC-C Inspection Checklist
Table 10mBSC Unit Inspection
Item
Description
1
Stable and normal.
2
Properly fastened
3
Screws and nuts screwed tightly, without missing flat washers and spring washers. Spring washers must be on the
top of flat washers.
4
No cable damage.
5
Clean, no smudges or dust.
6
Connections between metallic parts must be reliable, to assure reliable electric connectivity.
4.5.4 Cabling Inspection
Table 11 Cable Inspection
Item
Description
1
The connection of the cable is tight, not loose or damaged.
2
The cable shell not damaged.
3
Grounding cable is connected properly.
4
Cables are dressed neatly, power kept separate from signal.
5
The minimum bending radius of the cable is proper. (Shouldn’t be less than twenty times of the cable’s diameter.)
4.6 System Test
It is recommended to perform a system test after the physical installation and cabling has been inspected
and verified.
Use the following procedure to perform the system test:
Configure the attenuation both of the forward path and reverse path
Configure the parameters of Host Unit
VSWR testing: sweep test of cables and antenna
Configure the parameters of Remote Unit
Signal testing: indoor signal level testing
Effect testing: CQT/DT testing
Coverage Optimize: based on the signal & effect testing result, adjust the mBSC parameters to
optimize the coverage