Page 65
5.5.2 System Alarms
The MBSC0800-040-RU provides alarm indications for equipment malfunctions or for conditions that place
the out of standard operating range (such as over-power). A complete list of alarm events, and the
originating product module, is provided in Table 15System Alarms.
These events are enabled by default factory settings, but can be disabled if desired.
These alarm events can be observed in multiples ways:
- In the EMS Local GUI in the network topology view and corresponding component parameter
windows
- In the Monitor window of the remote EMS Server
- As SNMP traps issued by the remote EMS Server (if enabled)
Table 15System Alarms
Item
Equipment
Module
Alarm
ID
Alarm Name
Description
1
Host Unit
RCU
401500
Host/Remote Link
Optical RX signal is detected by the FIU
but no logical connection exists to the
Remote Node (CM)
2
423000
System Temperature
A system over-temperature alarm has
been reported
3
Host Unit
FIU
401500
Host/Remote Link
Optical RX signal is detected by the FIU
but no logical connection exists to the
Remote Node (CM)
4
422000
Optical Transceiver 1
Low/No optical signal is detected on Link
1
5
422100
Optical Transceiver 2
Low/No optical signal is detected on Link
2
6
Remote
Node
CM
401500
Host/Remote Link
Optical RX signal is detected by the CM
but no logical connection exists to the
Host Unit (FIU)
7
423000
System Temperature
A system over-temperature alarm has
been reported
8
400100
Power Down
Power has been lost at the Remote Node
(internal battery backup enables alarm
delivery)
9
Remote
Node
RU
PA
401920
PA Over VSWR
High VSWR detected at output of PA
10
427000
PA Over Output Power
PA output power exceed threshold
11
401620
PA Over Driver
PA overdrive condition exists
12
400600
PA Over Temperature
Alarm
High temperature condition in final PA
stage
13
427100
PA Lower Gain Alarm
Low gain condition (< 10dB) detected