User's Manual

mBSC081921-12 System
Operation Manual Issue 2
© 2009, Bravo Tech Inc. Page 18
There is the rule to define the Equipment Code for Remote Unit.
Warning: Equipment Code for RU should be followed the numbering rule for normal
operation. The conflicted Cdoe may casue for the failure of configuration of the system.
The code will be defined with the combination of Slot ID and Port number for FIU
module in Host Unit as shown in Table 3-1. Maximum 6 FIU modules can be installed in
one HU. And the slot number is started with “1” from the left side module to right side
module.
Table 3-1. Rule for numbering the Equipment Code
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
FC/APC1 0
FC/APC2 1
Slot #1 0 0 1
Slot #2 0 1 0
Slot #3 0 1 1
Slot #4 1 0 0
Slot #5 1 0 1
Slot #6
1 1 0
RU
Information
0 0 0 0
Note
1.
Slot # is numbered sequentially starting “1” from left side slot in HU
8. Figure 3-11 shows the completion of the system configuration and adding Host unit and Remote
Units in NMS.
Figure 3-11. Completion of the System Configuration