User's Manual

mBSC0800S-005-RUCM11
MBSC2100-005-RUCM11 April 15, 2013
Page 36
Figure 31 RF Inter-Connect between RTM and Single-band RU
4.4.1.2 Antenna Cable Connection
Route a coaxial antenna cable from the antenna to the equipment enclosure. The cable must be terminated
with the proper connector for connecting to the antenna port on the panel of BCM enclosure.
Below is the procedure to install the antenna cable:
1. Remove the dust cap from the DIN type female connector located on the panel of the BCM
enclosure.
2. Route the coaxial antenna cable to the panel of the BCM enclosure panel.
3. Cut the antenna cable to the required length and terminate with the proper connector.
4. Connect the antenna cable to the BCM port.
4.4.1.3 Optical Connections
The optical interface between the RTM enclosure and the Host Unit is supported by duplex Tx/Rx optical
port(s). Each optical port consists of aE2000/APC optical adapter which is mounted on the RTM enclosure
panel. A single mode, E2000/APC patch cord may be used.
Use the following steps to connect the optical fibers:
1. Obtain one patch cord which is sufficient length to reach from fiber optic distribution box to RTM
panel.
2. Remove the dust caps the optical ports and from the patch cord connectors that will be connected.
3. Clean each patch cord connector following the patch cord supplier’s recommendation.
4. Screw-thread secures the patch cord connector into the optical port on the fiber optic distribution
box.