5.5.2 System Alarms
The MBSC2500-005-RUCM11 provides alarm indications for equipment malfunctions or for conditions that
place the out of standard operating range (such as over-power). A complete list of alarm events, and the
originating product module, is provided in Table 16System Alarms.
These event
s are enabled by default factory settings, but can be disabled if desired.
These alarm events can be observed in multiples ways:
- In the EMS Local GUI in the network topology view and corresponding component parameter
windows
- In the Monitor window of the remote EMS Server
- As SNMP traps issued by the remote EMS Server (if enabled)
Table 16System Alarms
Item Equipment Module
Alarm
ID
AlarmName Description
1 401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheFIU
butnologicalconnectionexiststothe
RemoteNode(CM)
2
HostUnit RCU
423000 SystemTemperature
Asystemover‐temperaturealarmhas
beenreported
3 401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheFIU
butnologicalconnectionexiststothe
RemoteNode(CM)
4 422000 OpticalTransceiver1
Low/NoopticalsignalisdetectedonLink
1
5
HostUnit FIU
422100 OpticalTransceiver2
Low/NoopticalsignalisdetectedonLink
2
6 401500 Host/RemoteLink
OpticalRXsignalisdetectedbytheCM
butnologicalconnectionexiststothe
HostUnit(FIU)
7 423000 SystemTemperature
Asystemover‐temperaturealarmhas
beenreported
408301 Fan1Alarm Fan1isnon‐functioning(lowcurrent)
408302 Fan2Alarm Fan2isnon‐functioning(lowcurrent)
8
Remote
Node
RTM
400100 PowerDown
PowerhasbeenlostattheRemoteNode
(internalbatterybackupenablesalarm
delivery)
9 401920 PAOverVSWR HighVSWRdetectedatoutputofPA
10
427000 PAOverOutputPower PAoutputpowerexceedthreshold