User's Manual
Table Of Contents
- Document History
- Revision History
- GENERAL SAFETY PRECAUTIONS
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- Introduction
- Figure 1Block Diagram of Host Unit
- Figure 2 Block Diagram of Remote Node
- Safety
- System Overview and Unit Description
- Figure 3mBSC System Functional Overview
- Figure 4 Host Unit
- Figure 5BIU
- Figure 6FIU
- Figure 7 PSU
- Figure 8RCU
- Table 1 Host Unit User Interface
- Front Panel
- Rear Panel
- Figure 10Fiber CM-BTS/ANT Enclosure Outline
- Figure 11Fiber CM-BTS/ANT Interior Layout
- Table 6Fiber CM-BTS/ANT Enclosure User Interface
- Figure 12Fiber CM-BTS/ANT Enclosure User Interface
- Table 7Single-band BDA Enclosure User Interface
- Figure 14 Single-band RU Enclosure User Interface
- Table 8 Indicator Description
- Table 9Shroud Specification
- System Installation
- Figure 17 Mounting Brackets for 19” Rack Installation
- Figure 18Host Unit-19” Rack Mounting View
- Figure 19Host Unit Grounding Stud
- Figure 20 Grounded Host Unit
- Figure 21 BTS QMA Coaxial Cable Connection
- Figure 23E2000 Fiber Optic Port on Host Unit FIU
- Figure 2448VDC Host Power Connection
- Figure 25IP Connection for local GUI Control
- Figure 26Modem Port on RCU (DB9 male)
- Figure 27 Mounting Panel Mounting
- Figure 28Mount the Remote Unit on the Mounting Panel
- Figure 30Grounding Stud
- Figure 31 Grounding Wire the Ring Terminal
- SMA Coaxial Cable Inter-connection on Fiber CM-BTS/ANT Enclosure
- SMA Coaxial Cable Inter-connection on Single-band Enclosure
- DIN(7/16) Coaxial Cable Inter-connection on Single-band RU Enclosure
- N Type Coaxial Cable Inter-connection on CM-ANT Enclosure
- Figure 34Fiber Optic Cable Connection to Fiber CM-BTS Enclosure
- Warning
- Figure 35 AC Power Junction Box
- Figure 364-Pin AC Power Connector
- Figure 39 Flow Chart of System Debugging
- System Monitoring &Configuration
- Figure 40– EMS Local GUI Login
- Figure 41- Main Page Expanded Topology
- Figure 42- Main Page Summary View
- Figure 43- RCU Component View
- Figure 44- Main Page Equipment Status
- Figure 45- FIU Optical Power Levels
- Figure 46- CM Optical Power Levels
- Table 15System Alarms
- Maintenance
- Figure 56Host Unit Trouble Shooting
- Figure 57Remote Unit Trouble Shooting
- Terms, Acronyms & Abbreviations
- Packing List
- IC Radiation Exposure Statement
- IC Déclaration sur la radio exposition
MBSC-C RU
MBSC-C RU December 15, 2015
Page 28
Figure 21 BTS QMA Coaxial Cable Connection
5. Dress and secure cable at the Host Unit.
6. The RF inter-connection between the BIU and the FIU uses QMA to QMA jumper cables supplied
with the mBSC-C equipment.
4.3.2.3 Optical Connections
The optical interface between the Host Unit and the Remote Node is supported by an E2000/APC optical
adapter which is mounted on the FIU front panel. A single mode, E2000/APC patch cord may be used to
connect the Host Unit with Remote Node.
Use the following steps to connect the optical fibers:
1. Obtain one patch cord which is sufficient length to reach from Host Unit to the Remote Node.
2. Clean each patch cord connector following the patch cord supplier’s recommendation.
3. Push and secure the patch cord connector into the desired optical port on the Host Unit FIU
Figure 22Single Mode Patch Cord(E2000/APC)
Figure 23E2000 Fiber Optic Port on Host Unit FIU
4. Route the patch cords from the Host Unit to the Remote Node.