Figure 28IP Connection for local GUI Control
4.3.2.6 Modem Connection (optional)
For remote operation, the mBSC-C system provides a serial modem connecter for external modem
connection.
To connect a modem with the host unit:
1. Route the modem cable between the modem and host unit.
2. Connect the modem cable with a DB9 female plug to the modem socket on the host unit’s RCU
front panel.
Figure 29Modem Port on RCU (DB9 male)
3. Connect the modem cable with DB9 male plug to the modem serial port.
4.4 Remote Node Installation
The remote unit is a 19” 4U equipment shelf. When loading the remote unit in a rack, make sure the
mechanical loading of the rack is even to avoid a hazardous condition. The rack should safely support the
combined weight of all the equipment and be securely anchored. Installing the remote unit in a room with
sufficient air circulation is recommended as the maximum ambient temperature for remote unit is 60°C.
remote unit install as same as HU device. Please refer to chapter 4.3.1.